How sensitive is Ninja 5 heatsink to airflow changes?

How we were testing

The original fans are quite slow, so it was especially fascinating to watch how the heatsink behaved with settings that are not intended for it – with a proper airflow through the ribs. Not only with both fans, but also with just one. Some results really surprised us. And the temperatures in the passive mode are very interesting too, one of the reasons why Ninja coolers have such a good reputation.

Bonus tests of coolers are a regular extension of standard reviews. In addition to cooling efficiency around the socket, they include testing and comparison of heatsinks using the same fans, as well as fully passive operation without any active cooling. And also other various tests that might be interesting for a particular cooler.

How we were testing

During the tests, we also measured CPU MOSFETs heating at 33 and 39 dBA. We put the sensor right into the heatsink. These tests always begin with the same starting temperature (35 °C). Although Gigabyte is known for an excellent cooling of its power supply and manages to maintain very attractive temperatures, it is still easy to determine which of the coolers more or less keeps doing a good job cooling the critical components.

The fans were aligned in such a way that they do not exceed over the top rib because it would be pointless there. It is more important to swirl the air in the lower parts. This was still measured with the default fans.

In the next phase of the tests, the original fans were replaced by the reference fans to create the performance comparison of the heatsinks with the same fans. These results might come in handy when you want to replace the default fans. Usually because they are too fast or too slow (and inefficient), or they produce disturbing sounds, or for whatever reason based on personal preferences.

Optimal candidates for such tests are the “industrial” Noctua NF-F12 iPPC fans. Thanks to their wide range, we could test with a very high flow and at a very low noise level. We increased the flow of the system fans (4× 1200 rpm) only in 24 V mode (2000 rpm without any problems). For a better comparison, we also included the tests with standard 4× 550 rpm. After reducing the voltage to 15 V, the fans were relatively quiet (1290 rpm) and at 9 volts they were running at 765 rpm only, which could be especially challenging for large two-tower heatsinks and larger liquid coolers. We replaced the reference fans with the number corresponding to the original set. Usually one or two. For a better orientation, it is marked in the charts (1/2 ×).

   

Finally, the coolers competed with each other without a fan. The processor we used was Core i7-5930K (TDP 140 W) with Vcore 0.9 V, which had 25 W lower power consumption than with default settings. These tests took longer than those before, 900 seconds. Most coolers cannot handle this. After 95 ºC, tests were interrupted and considered unsuccessful. Therefore, temperatures in idle are also interesting. We used traditional configuration of system cooling and airflow.

Extra test: Configuration with one fan only. It’s an atypical setting for the fifth model, but all previous Ninjas (standard versions) were supplied with just one fan. Is the final effect of two fans the same as on the paper?


  •  
  •  
  •  
Flattr this!

Endorfy Fera 5 Black – Bestseller on the way to darkness

Today marks the launch of a new version of the popular Endorfy Fera 5 cooler, with the Black attribute. The name suggests that this cooler has a matte black finish, which will be appreciated especially by fans of minimalist PC builds. Of course, it will have to be tested whether this finish has a negative effect on cooling efficiency or whether there is any deterioration in acoustics. So let’s venture into the dark future of Endorfy coolers together. Read more “Endorfy Fera 5 Black – Bestseller on the way to darkness” »

  •  
  •  
  •  

Display on a CPU cooler: DeepCool AK620 Digital preview

For coolers (but also cases) with the Digital attribute, DeepCool creates a built-in display. Its implementation is minimalist in spirit, doesn’t increase the price significantly, and can be considered useful. With regard to monitoring CPU temperatures and load intensity, it’s a thematic value added, which we’ll now look at in the context of the powerful AK620 (Digital) dual-tower cooler. Read more “Display on a CPU cooler: DeepCool AK620 Digital preview” »

  •  
  •  
  •  

EK-Nucleus CR360 Lux White – Simply gorgeous liquid cooler

I probably don’t need to introduce EK Water Blocks here. It produces high-end components for water loops and for the last few years it has been using its experience in this field in designing AIO coolers as well. The EK-Nucleus CR360 Lux represents the top of the current range and will impress you above all with its clean and elegant design. With good test results, one can expect an attractive ratio of price, quality and efficiency, considering its price. Read more “EK-Nucleus CR360 Lux White – Simply gorgeous liquid cooler” »

  •  
  •  
  •  

Comments (5) Add comment

  1. This test is hard to read. Why are some graphs empty? What is @24V? Is it 2x 12V or do you actually put 24V through the fans?

    1. Sorry for late reply. Passive cooling mean that heatsink haven’t a fan on its ribs but the system cooling is active.