Thermalright X-Silent 120: Quiet operation for a bargain

The basis of the methodology, the wind tunnel

To write that we have something mapped out to the last detail is perhaps too bold, but after proper preparation, few pieces of hardware are as easy to evaluate as fans. Of course, this had to be preceded by long preparations, developing a methodology, but you already know the story. What you don’t know yet is the first fruit, or rather the results of Akasa, SilentiumPC, SilverStone, Xigmatek or more exotic Reeven fans.

The basis of the methodology, the wind tunnel

Before you start reading the methodology with all the details, take a look at the test tunnel as a whole. This is the heart of the whole system, to which other arteries are connected (manometer, vibrometer, powermeter, …). The only solid part of the tunnel from the measuring instruments is the anemometer.

The shape of the wind tunnel is inspired by the Venturi tube, which has long been used to measure the flow of liquids and gasses. The Venturi effect for wind speed measuring is also known from the aerospace industry. However, the design for measuring computer fans has its own specificities, which this proposal of ours reflects.

The individual parameters of the HWC wind tunnel for fan tests are the result of physical simulations and practical debugging. All the details (folds, material or finish used) have a rationale behind them and are designed this way for a specific reason. We will discuss the individual design details in turn in the description of the sub-variable measurements.

Now we will briefly elaborate on some things that do not fit thematically into the text of the following chapters. Namely, for example, that the skeleton of the wind tunnel is the work of a 3D printer (PLA). The rough print was, of course, then thoroughly machined by grinding, fusing, polishing and varnishing. Especially important is the smooth finish of the interior walls.

When joining the individual parts, the emphasis was on making sure that they fit together flawlessly, that they were sealed flawlessly (we will come back to this when we describe the test procedures for pressure measurement), but also that the joints were not loosened by use. Everything is disassemblable for servicing purposes, but it is ensured that the properties are maintained during use and, for example, even under the stress of vibration. The threads are secured with either lock nuts or thread-locking fluid. It depends on which is more suitable in which place.

When the wind tunnel is not in use, it is enclosed in a dust-tight chamber. In addition to the technical equipment and its correct storage, it is also important for objective outputs that all measuring instruments are calibrated according to the standard. Without this, it would be impossible to stand behind your results and rely on the manufacturers’ specifications. Calibration protocols are therefore an important part of the methodology. Testing is carried out at an ambient air temperature of 21–21.3 °C, humidity is approximately 45 % (± 2 %).

Fans come to us for testing in at least two pieces of the same model. If the deviations of any of the measured values are greater than 5 %, we also work with a third or fourth sample and the average value is formed by the results of the fans that came out the most similar and the differences between them fit under 5 %.


  •  
  •  
  •  
Flattr this!

Corsair RS Max: Fans that can rise to the top

With the RS Max fans, Corsair is aiming really high. Across the most popular 120 and 140mm formats, it has incorporated technically what should define perhaps the most efficient fans of their kind. Especially when it comes to the 140mm variant. It too is 30mm thick, which combined with the curved LCP blades makes it a theoretical favorite to win many “first places”. Read more “Corsair RS Max: Fans that can rise to the top” »

  •  
  •  
  •  

Noctua: New 140 mm fans to premiere on a CPU cooler

Noctua’s long-awaited next-gen fans in the 140mm format have experienced a setback in their planned release, but they also haven’t. They have indeed been delayed from the second to third quarter of 2024 in terms of standalone availability, but they should be out soon together with the cooler that replaces the NH-D15 at the top of the lineup. In addition, it’s also been somewhat declassified which of the “older” projects is nearing completion. Read more “Noctua: New 140 mm fans to premiere on a CPU cooler” »

  •  
  •  
  •  

PCCooler CPS F5 R120 BK: Mid-range attacking the top

Some really attractive things are often overlooked or given less attention than they deserve, for various reasons. This is somewhat the case with the technically remarkable fan from PCCooler CPS – the F5 R120. This 120 mm fan with its features is in the company of the most prominent names, although it has its weaknesses as well. These may or may not interest you either. It depends on the use case. Read more “PCCooler CPS F5 R120 BK: Mid-range attacking the top” »

  •  
  •  
  •  

Leave a Reply