Thermalright X-Silent 120: Quiet operation for a bargain

… and airflow

To write that we have something mapped out to the last detail is perhaps too bold, but after proper preparation, few pieces of hardware are as easy to evaluate as fans. Of course, this had to be preceded by long preparations, developing a methodology, but you already know the story. What you don’t know yet is the first fruit, or rather the results of Akasa, SilentiumPC, SilverStone, Xigmatek or more exotic Reeven fans.

… and airflow

With airflow measurements, we can well explain why the test tunnel is shaped the way it is. It doesn’t consist of two parts just so that the “exhaust” can be conveniently clogged for pressure measurements. The anemometer (i.e. the wind speed measuring instrument) is held together by two parts, two formations, through the flanges.
The front part, at the beginning of which the fan is mounted, becomes steadily narrower and from about two thirds of the way through the cross-section is smaller than that of a 120 mm fan. The reason for this is that the cross-section of the anemometer is always smaller than that of the fans tested. The taper towards the anemometer fan is as smooth as could be chosen and the tunnel walls are smooth. This has minimized the occurrence of unnatural turbulence.
The difference between the cross section at the intake (fan under test) and at the constriction point (anemometer) also means a difference in dynamic pressure, the principles of the Venturi effect apply here. In order to avoid distortion at this level and to ensure that the fan airflow is not different from what it actually is, the Bernoulli equation must be applied to the measured values (for maximum accuracy, the calculation also takes into account the internal cross-sectional area of the anemometer, i.e. its inactive part ). After all this, it is again possible to confront our results with the paper parameters.

We use an Extech AN300 anemometer with a large 100 mm fan for the measurements. Its big advantage over other anemometers is that it is made for bidirectional sensing. This allows tests at different fan orientations. However, the “pull” position is more suitable or accurate for measurements, even though it may not seem so at first glance, but we’ll explain.

Here, we get to the second part of the tunnel, the part behind the anemometer. It is part of the whole device, mainly to allow a laminar flow of air to arrive at the rotor of the anemometer. Otherwise, uncontrolled side whirls would be reflected in the results, which are inconsistent with accurate measurements. Therefore, we will test the flow in the pull position. If anyone would like us to elaborate more on this topic, we can elaborate further at any time in the discussion below the article. Ask away. 🙂

The rear of the tunnel ensures, among other things, that the air supply to the anemometer fan is laminar

In connection with the anemometer, we will return a little more to the noise measurements and to the setting of modes according to fixed noise levels. It may have occurred to you as you were reading that the anemometer fan is also a source of sound that needs to be filtered out when testing fans. For this reason, we insert a belay pad between the frame and the anemometer fan before each measurement and mode setting according to the fixed noise level.


  •  
  •  
  •  
Flattr this!

Corsair RS Max: Fans that can rise to the top

With the RS Max fans, Corsair is aiming really high. Across the most popular 120 and 140mm formats, it has incorporated technically what should define perhaps the most efficient fans of their kind. Especially when it comes to the 140mm variant. It too is 30mm thick, which combined with the curved LCP blades makes it a theoretical favorite to win many “first places”. Read more “Corsair RS Max: Fans that can rise to the top” »

  •  
  •  
  •  

Noctua: New 140 mm fans to premiere on a CPU cooler

Noctua’s long-awaited next-gen fans in the 140mm format have experienced a setback in their planned release, but they also haven’t. They have indeed been delayed from the second to third quarter of 2024 in terms of standalone availability, but they should be out soon together with the cooler that replaces the NH-D15 at the top of the lineup. In addition, it’s also been somewhat declassified which of the “older” projects is nearing completion. Read more “Noctua: New 140 mm fans to premiere on a CPU cooler” »

  •  
  •  
  •  

PCCooler CPS F5 R120 BK: Mid-range attacking the top

Some really attractive things are often overlooked or given less attention than they deserve, for various reasons. This is somewhat the case with the technically remarkable fan from PCCooler CPS – the F5 R120. This 120 mm fan with its features is in the company of the most prominent names, although it has its weaknesses as well. These may or may not interest you either. It depends on the use case. Read more “PCCooler CPS F5 R120 BK: Mid-range attacking the top” »

  •  
  •  
  •  

Leave a Reply

Your email address will not be published. Required fields are marked *