Dynamic X2 GP-12 PWM: Fractal Design knows what works in cases

The basis of the methodology, the wind tunnel

To write that we have something mapped out to the last detail is perhaps too bold, but after proper preparation, few pieces of hardware are as easy to evaluate as fans. Of course, this had to be preceded by long preparations, developing a methodology, but you already know the story. What you don’t know yet is the first fruit, or rather the results of Akasa, SilentiumPC, SilverStone, Xigmatek or more exotic Reeven fans.

The basis of the methodology, the wind tunnel

Before you start reading the methodology with all the details, take a look at the test tunnel as a whole. This is the heart of the whole system, to which other arteries are connected (manometer, vibrometer, powermeter, …). The only solid part of the tunnel from the measuring instruments is the anemometer.

The shape of the wind tunnel is inspired by the Venturi tube, which has long been used to measure the flow of liquids and gasses. The Venturi effect for wind speed measuring is also known from the aerospace industry. However, the design for measuring computer fans has its own specificities, which this proposal of ours reflects.

The individual parameters of the HWC wind tunnel for fan tests are the result of physical simulations and practical debugging. All the details (folds, material or finish used) have a rationale behind them and are designed this way for a specific reason. We will discuss the individual design details in turn in the description of the sub-variable measurements.

Now we will briefly elaborate on some things that do not fit thematically into the text of the following chapters. Namely, for example, that the skeleton of the wind tunnel is the work of a 3D printer (PLA). The rough print was, of course, then thoroughly machined by grinding, fusing, polishing and varnishing. Especially important is the smooth finish of the interior walls.

When joining the individual parts, the emphasis was on making sure that they fit together flawlessly, that they were sealed flawlessly (we will come back to this when we describe the test procedures for pressure measurement), but also that the joints were not loosened by use. Everything is disassemblable for servicing purposes, but it is ensured that the properties are maintained during use and, for example, even under the stress of vibration. The threads are secured with either lock nuts or thread-locking fluid. It depends on which is more suitable in which place.

When the wind tunnel is not in use, it is enclosed in a dust-tight chamber. In addition to the technical equipment and its correct storage, it is also important for objective outputs that all measuring instruments are calibrated according to the standard. Without this, it would be impossible to stand behind your results and rely on the manufacturers’ specifications. Calibration protocols are therefore an important part of the methodology. Testing is carried out at an ambient air temperature of 21–21.3 °C, humidity is approximately 45 % (± 2 %).

Fans come to us for testing in at least two pieces of the same model. If the deviations of any of the measured values are greater than 5 %, we also work with a third or fourth sample and the average value is formed by the results of the fans that came out the most similar and the differences between them fit under 5 %.


  •  
  •  
  •  
Flattr this!

ARGB Asus fan (TUF TR120) now with a thicker profile

It’s evident from the design of the new TUF Gaming TR120 fan that Asus has diagnosed the weaknesses of its predecessor (and, from the current perspective, weaker model) well and worked on them with a view to achieving better results. These key changes are also easy to point out, and it’s likely that across all possible scenarios this will be one of the most aerodynamically efficient LED fans in the 120mm format. Read more “ARGB Asus fan (TUF TR120) now with a thicker profile” »

  •  
  •  
  •  

Arctic P14 PWM PST CO or ball vs. fluid bearings

Longer life in exchange for more noise? These are also some of the agenda items we’ll cover in our comparison of the Arctic P14 CO fan with the fluid bearing variant (P14). These are actually the main points. In any case, the ball bearings in the more expensive variant of these fans also have specific features that can be easily observed and distinguished even in normal, “home” use. Read more “Arctic P14 PWM PST CO or ball vs. fluid bearings” »

  •  
  •  
  •  

Arctic P14 PWM PST: Unbeatable in its segment

What is fascinating about the Arctic P14 is the particularly high contrast of price to (cooling) efficiency. These fans are among the cheapest, while at the same time achieving top results with respect to all 140 mm fans in terms of airflow per unit of noise. And that’s even through obstacles. Arctic has made almost the maximum out of the funds available to produce the fan, and it is definitely worth it. Read more “Arctic P14 PWM PST: Unbeatable in its segment” »

  •  
  •  
  •  

Comments (2) Add comment

  1. I’m wondering how reviewed fans relate to 140mm version, Dynamic X2 GP-14.
    I have three of them mounted as stock fans in Fractal Design Meshify 2 case and 3x Fluctus 120 PWM in drawer.
    GP-12 are clearly inferior to Fluctus, but what about 140mm GP-14 vs 120mm Fluctus when used as 2x intake and 1x exhaust case fan?

    1. Sooner or later we will get to such a comment. Anyway, these are structurally completely different designs, where the Fluctus 120 PWM is handicapped by higher tonal peaks at lower frequencies and with the Dynamic X2 GP-14 it might be again (like the Dynamic X2 GP-12 PWM) a relatively noisier, gently whirring motor. We’ll see…

Leave a Reply

Your email address will not be published. Required fields are marked *