Arctic BioniX F120: The efficient fan that loses to obstacles

The basis of the methodology, the wind tunnel

To write that we have something mapped out to the last detail is perhaps too bold, but after proper preparation, few pieces of hardware are as easy to evaluate as fans. Of course, this had to be preceded by long preparations, developing a methodology, but you already know the story. What you don’t know yet is the first fruit, or rather the results of Akasa, SilentiumPC, SilverStone, Xigmatek or more exotic Reeven fans.

The basis of the methodology, the wind tunnel

Before you start reading the methodology with all the details, take a look at the test tunnel as a whole. This is the heart of the whole system, to which other arteries are connected (manometer, vibrometer, powermeter, …). The only solid part of the tunnel from the measuring instruments is the anemometer.

The shape of the wind tunnel is inspired by the Venturi tube, which has long been used to measure the flow of liquids and gasses. The Venturi effect for wind speed measuring is also known from the aerospace industry. However, the design for measuring computer fans has its own specificities, which this proposal of ours reflects.

The individual parameters of the HWC wind tunnel for fan tests are the result of physical simulations and practical debugging. All the details (folds, material or finish used) have a rationale behind them and are designed this way for a specific reason. We will discuss the individual design details in turn in the description of the sub-variable measurements.

Now we will briefly elaborate on some things that do not fit thematically into the text of the following chapters. Namely, for example, that the skeleton of the wind tunnel is the work of a 3D printer (PLA). The rough print was, of course, then thoroughly machined by grinding, fusing, polishing and varnishing. Especially important is the smooth finish of the interior walls.

When joining the individual parts, the emphasis was on making sure that they fit together flawlessly, that they were sealed flawlessly (we will come back to this when we describe the test procedures for pressure measurement), but also that the joints were not loosened by use. Everything is disassemblable for servicing purposes, but it is ensured that the properties are maintained during use and, for example, even under the stress of vibration. The threads are secured with either lock nuts or thread-locking fluid. It depends on which is more suitable in which place.

When the wind tunnel is not in use, it is enclosed in a dust-tight chamber. In addition to the technical equipment and its correct storage, it is also important for objective outputs that all measuring instruments are calibrated according to the standard. Without this, it would be impossible to stand behind your results and rely on the manufacturers’ specifications. Calibration protocols are therefore an important part of the methodology. Testing is carried out at an ambient air temperature of 21–21.3 °C, humidity is approximately 45 % (± 2 %).

Fans come to us for testing in at least two pieces of the same model. If the deviations of any of the measured values are greater than 5 %, we also work with a third or fourth sample and the average value is formed by the results of the fans that came out the most similar and the differences between them fit under 5 %.


  •  
  •  
  •  
Flattr this!

Arctic S12038-4K: Massive fan for harsh conditions

A totally different type of fan than the ones we normally deal with. The Arctic S12038-4K is designed for high-performance servers, which is also reflected in its features. Very high airflow is provided by as much as 4000 rpm. And in order to ensure that the cooling performance does not drop significantly even through obstacles, the “extreme” Arctic fan has a profile that is as thick as 38 mm. Read more “Arctic S12038-4K: Massive fan for harsh conditions” »

  •  
  •  
  •  

Arctic Freezer 4U SP5 details: A “two for one” cooler

Arctic’s new cooler – the Freezer 4U SP5 – is a bit different from the coolers we normally cover. It’s designed for the high-end AMD SP5 platform, which is reflected in its unconventional base. At first glance, it looks like the cooler has two bases, and in fact, its entire structure is reminiscent of two mainstream Freezer coolers stuck together. Such a design makes sense though. Read more “Arctic Freezer 4U SP5 details: A “two for one” cooler” »

  •  
  •  
  •  

Latest Arctic Freezer coolers get LGA 1200/115x support

Roughly half a year after the release of the Freezer 36 and Liquid Freezer III, Arctic has reconsidered its decision to support, or rather not support, older Intel platforms. Initially, you couldn’t even install these coolers on Rocket Lake processors. But that is now changing. However, you need to be careful and add a new mounting kit to your cart in addition to the cooler if you want to use it on LGA 1200 or even older LGA 115x processors. Read more “Latest Arctic Freezer coolers get LGA 1200/115x support” »

  •  
  •  
  •  