Arctic BioniX F120: The efficient fan that loses to obstacles

… and airflow

To write that we have something mapped out to the last detail is perhaps too bold, but after proper preparation, few pieces of hardware are as easy to evaluate as fans. Of course, this had to be preceded by long preparations, developing a methodology, but you already know the story. What you don’t know yet is the first fruit, or rather the results of Akasa, SilentiumPC, SilverStone, Xigmatek or more exotic Reeven fans.

… and airflow

With airflow measurements, we can well explain why the test tunnel is shaped the way it is. It doesn’t consist of two parts just so that the “exhaust” can be conveniently clogged for pressure measurements. The anemometer (i.e. the wind speed measuring instrument) is held together by two parts, two formations, through the flanges.
The front part, at the beginning of which the fan is mounted, becomes steadily narrower and from about two thirds of the way through the cross-section is smaller than that of a 120 mm fan. The reason for this is that the cross-section of the anemometer is always smaller than that of the fans tested. The taper towards the anemometer fan is as smooth as could be chosen and the tunnel walls are smooth. This has minimized the occurrence of unnatural turbulence.
The difference between the cross section at the intake (fan under test) and at the constriction point (anemometer) also means a difference in dynamic pressure, the principles of the Venturi effect apply here. In order to avoid distortion at this level and to ensure that the fan airflow is not different from what it actually is, the Bernoulli equation must be applied to the measured values (for maximum accuracy, the calculation also takes into account the internal cross-sectional area of the anemometer, i.e. its inactive part ). After all this, it is again possible to confront our results with the paper parameters.

We use an Extech AN300 anemometer with a large 100 mm fan for the measurements. Its big advantage over other anemometers is that it is made for bidirectional sensing. This allows tests at different fan orientations. However, the “pull” position is more suitable or accurate for measurements, even though it may not seem so at first glance, but we’ll explain.

Here, we get to the second part of the tunnel, the part behind the anemometer. It is part of the whole device, mainly to allow a laminar flow of air to arrive at the rotor of the anemometer. Otherwise, uncontrolled side whirls would be reflected in the results, which are inconsistent with accurate measurements. Therefore, we will test the flow in the pull position. If anyone would like us to elaborate more on this topic, we can elaborate further at any time in the discussion below the article. Ask away. 🙂

The rear of the tunnel ensures, among other things, that the air supply to the anemometer fan is laminar

In connection with the anemometer, we will return a little more to the noise measurements and to the setting of modes according to fixed noise levels. It may have occurred to you as you were reading that the anemometer fan is also a source of sound that needs to be filtered out when testing fans. For this reason, we insert a belay pad between the frame and the anemometer fan before each measurement and mode setting according to the fixed noise level.


  •  
  •  
  •  
Flattr this!

Arctic S12038-4K: Massive fan for harsh conditions

A totally different type of fan than the ones we normally deal with. The Arctic S12038-4K is designed for high-performance servers, which is also reflected in its features. Very high airflow is provided by as much as 4000 rpm. And in order to ensure that the cooling performance does not drop significantly even through obstacles, the “extreme” Arctic fan has a profile that is as thick as 38 mm. Read more “Arctic S12038-4K: Massive fan for harsh conditions” »

  •  
  •  
  •  

Arctic Freezer 4U SP5 details: A “two for one” cooler

Arctic’s new cooler – the Freezer 4U SP5 – is a bit different from the coolers we normally cover. It’s designed for the high-end AMD SP5 platform, which is reflected in its unconventional base. At first glance, it looks like the cooler has two bases, and in fact, its entire structure is reminiscent of two mainstream Freezer coolers stuck together. Such a design makes sense though. Read more “Arctic Freezer 4U SP5 details: A “two for one” cooler” »

  •  
  •  
  •  

Latest Arctic Freezer coolers get LGA 1200/115x support

Roughly half a year after the release of the Freezer 36 and Liquid Freezer III, Arctic has reconsidered its decision to support, or rather not support, older Intel platforms. Initially, you couldn’t even install these coolers on Rocket Lake processors. But that is now changing. However, you need to be careful and add a new mounting kit to your cart in addition to the cooler if you want to use it on LGA 1200 or even older LGA 115x processors. Read more “Latest Arctic Freezer coolers get LGA 1200/115x support” »

  •  
  •  
  •  

Leave a Reply

Your email address will not be published. Required fields are marked *