Arctic BioniX F120: The efficient fan that loses to obstacles

Static pressure measurement…

To write that we have something mapped out to the last detail is perhaps too bold, but after proper preparation, few pieces of hardware are as easy to evaluate as fans. Of course, this had to be preceded by long preparations, developing a methodology, but you already know the story. What you don’t know yet is the first fruit, or rather the results of Akasa, SilentiumPC, SilverStone, Xigmatek or more exotic Reeven fans.

Static pressure measurement…

Finally, it is time to move further down the tunnel a bit. Just behind the fan is a static pressure sensing probe. Its position has been chosen with maximum measurement efficiency in mind. In other words, the sensors are placed at the points of highest pressure (although this is virtually the same everywhere in the unconstrained part of the tunnel).

The Fieldpiece ASP2, which is connected to the Fieldpiece SDMN5 manometer, is used to measure the static pressure in the tunnel. The latter also allows measurements in millimetres of water column, but we measure in millibars. This is a more finely resolved base unit for this meter. And only from there we convert the measured values into mm H2O to allow easy comparison with what the manufacturers state.

Internal part of the probe to measure the static pressure inside the tunnel…

The difference in cross-section at the intake and exhaust (where the exhaust in this case is considered to be the anemometer) is related to the fact that the pressure increases in the narrowed part and with it the airflow. In order to avoid distortion at this level and to prevent the airflow from being stated as higher than it actually is, the Bernoulli equation must be applied to the measured values to compensate for the difference between the intake and exhaust cross-section (it also takes into account the motor housings). After this, it is again possible to confront our results with the paper parameters.

… and the external part leading to the manometer

The greater the difference between the manufacturer’s claimed values and ours, the less the specifications correspond to reality. If the claimed values are significantly higher, it is certainly an intention to artificially give an advantage to the fans on the market. However, if the manufacturer quotes a lower pressure value than we do, it points to something else. Namely, a weaker tightness of the measuring environment. The less tight the tunnel is, the lower the pressure you naturally measure. This is one of the things we tuned for an extremely long time, but in the end we ironed out all the weak spots. Whether it’s the passage for the probe itself, the flanges around the anemometer, even the anemometer frame itself, which is made up of two parts, needed to be sealed in the middle. Finally, the flap at the tunnel outlet must also be perfectly tight. That’s because static pressure has to be measured in zero airflow.

The furthest part from the fan – cap for static pressure measurements

But there is one thing that often lowers the pressure of the fans a bit. And that’s protruding anti-vibration pads in the corners or otherwise protruding corners. In other words, when the fan doesn’t fit perfectly to the mounting frame at the inlet, and there are small gaps around the perimeter, that also affects what you measure. But we have not gone into this because it is already a quality feature of the fan. In the same way, it will “stand out” and perform a bit weaker than it has the potential to do with better workmanship, even after application by the end user.


  •  
  •  
  •  
Flattr this!

For the price/performance! Arctic Freezer 36 A-RGB (White)

Even with two fans, this cooler is a very good option. Compared to similar and typically cheaper designs with four heatpipes, it can handle significantly higher loads. This is true on both the latest Intel platform (LGA 1851) and AMD Ryzen 9000 processors (AMD AM5). There is also a certain benefit to these things around cooling performance in mounting via a custom retention bracket (ILM) around the processor socket. Read more “For the price/performance! Arctic Freezer 36 A-RGB (White)” »

  •  
  •  
  •  

Arctic S12038-4K: Massive fan for harsh conditions

A totally different type of fan than the ones we normally deal with. The Arctic S12038-4K is designed for high-performance servers, which is also reflected in its features. Very high airflow is provided by as much as 4000 rpm. And in order to ensure that the cooling performance does not drop significantly even through obstacles, the “extreme” Arctic fan has a profile that is as thick as 38 mm. Read more “Arctic S12038-4K: Massive fan for harsh conditions” »

  •  
  •  
  •  

Arctic Freezer 4U SP5 details: A “two for one” cooler

Arctic’s new cooler – the Freezer 4U SP5 – is a bit different from the coolers we normally cover. It’s designed for the high-end AMD SP5 platform, which is reflected in its unconventional base. At first glance, it looks like the cooler has two bases, and in fact, its entire structure is reminiscent of two mainstream Freezer coolers stuck together. Such a design makes sense though. Read more “Arctic Freezer 4U SP5 details: A “two for one” cooler” »

  •  
  •  
  •  