Arctic P12 PWM PST A-RGB: Hoop? Anti-rumble rescue

Static pressure measurement…

The biggest shortcoming of Arctic’s original P-series fans is the rumbling sound profile. The manufacturer realized this and decided to do something about it. Sensibly, by implementing a hoop to eliminate the critical vibrations that are the source of the annoying acoustic profile. The implementation turned out well, and already the P12 A-RGB shows how much quieter it is compared to the older P12 model. And the list of improvements doesn’t end there.

Static pressure measurement…

Finally, it is time to move further down the tunnel a bit. Just behind the fan is a static pressure sensing probe. Its position has been chosen with maximum measurement efficiency in mind. In other words, the sensors are placed at the points of highest pressure (although this is virtually the same everywhere in the unconstrained part of the tunnel).

The Fieldpiece ASP2, which is connected to the Fieldpiece SDMN5 manometer, is used to measure the static pressure in the tunnel. The latter also allows measurements in millimetres of water column, but we measure in millibars. This is a more finely resolved base unit for this meter. And only from there we convert the measured values into mm H2O to allow easy comparison with what the manufacturers state.

Internal part of the probe to measure the static pressure inside the tunnel…

While we wrote when measuring noise levels that our results could not be compared with the parameters, that is no longer the case here. As long as the fan manufacturers do not embellish the parameters, they should quote approximately the same pressure values as our tests show. The most significant deviations can only arise at the level of varying accuracy of the measuring instruments, but these are negligible percentages.

…and the external part leading to the manometer

The greater the difference between the manufacturer’s claimed values and ours, the less the specifications correspond to reality. If the claimed values are significantly higher, it is certainly an intention to artificially give an advantage to the fans on the market. However, if the manufacturer quotes a lower pressure value than we do, it points to something else. Namely, a weaker tightness of the measuring environment. The less tight the tunnel is, the lower the pressure you naturally measure. This is one of the things we tuned for an extremely long time, but in the end we ironed out all the weak spots. Whether it’s the passage for the probe itself, the flanges around the anemometer, even the anemometer frame itself, which is made up of two parts, needed to be sealed in the middle. Finally, the flap at the tunnel outlet must also be perfectly tight. That’s because static pressure has to be measured in zero airflow.

The furthest part from the fan – cap for static pressure measurements

But there is one thing that often lowers the pressure of the fans a bit. And that’s protruding anti-vibration pads in the corners or otherwise protruding corners. In other words, when the fan doesn’t fit perfectly to the mounting frame at the inlet, and there are small gaps around the perimeter, that also affects what you measure. But we have not gone into this because it is already a quality feature of the fan. In the same way, it will “stand out” and perform a bit weaker than it has the potential to do with better workmanship, even after application by the end user.


  •  
  •  
  •  
Flattr this!

Arctic P14 PWM PST: Unbeatable in its segment

What is fascinating about the Arctic P14 is the particularly high contrast of price to (cooling) efficiency. These fans are among the cheapest, while at the same time achieving top results with respect to all 140 mm fans in terms of airflow per unit of noise. And that’s even through obstacles. Arctic has made almost the maximum out of the funds available to produce the fan, and it is definitely worth it. Read more “Arctic P14 PWM PST: Unbeatable in its segment” »

  •  
  •  
  •  

BeQuiet! Silent Wings 4 (BL117): A white choice for your case

The Silent Wings (Pro) 4 represent the pinnacle of computer fan range. The non-Pro variants stand out especially in system positions and are not well suited for radiators. This is by design and in line with the sort of “micro-segmentation” of BeQuiet. In a white design, like the one tested, it will be quite difficult to find other 140 mm fans that are quieter at comparable airflow. Read more “BeQuiet! Silent Wings 4 (BL117): A white choice for your case” »

  •  
  •  
  •  

Endorfy Stratus 140 PWM: Low price, high efficiency

The cheapest 140mm fan we’ve tested so far beats even significantly more expensive 120mm models at comparable noise levels. That’s because of the use of a larger cross-sectional area, as well as the efficient impeller geometry that the Stratus 140 PWM definitely has. “Cheap” fan doesn’t necessarily mean “weak”, though of course there are some compromises based on more limited manufacturing resources than with more expensive fans. Read more “Endorfy Stratus 140 PWM: Low price, high efficiency” »

  •  
  •  
  •  

Comments (5) Add comment

  1. This is a good study of the effect of rings. The blades are a bit shorter so there’s less airflow at the same noise level (despite higher static pressure), but it suppresses blade vibrations very effectively, improving the noise profile for fans using flexible blades.

    I am thinking that the increased static pressure may be partially be due to the increased hub size. It was mentioned by Noctua that the inner parts of the blades have less efficiency, and may even allow air to flow back, so an increased hub size may actually contribute to better static pressure. I think the Gentle Typhoon-like fans all have very similar, large motor hub size because of this.

    It’s also interesting to see that the official static pressure spec vs. the one you measured varies by so much between the P12 and the P12 ARGB. The official spec has the P12 having higher static pressure being higher than the ARGB version, yet it is opposite here.

    The rotor looks pretty much identical to that of the P12 Max, the other minor difference is the ribs in the stator. Are there any differences apart from blade material and the bearing (aside from RGB?) Perhaps this is the budget fan to get if you want to avoid the dual ball bearing noise of the P12 Max, even if you do not want or need RGB.

    1. Well, the best study would be with P14 rev. 1 vs. rev. 2, if the same motor is used across revisions and the only difference is really in the (non)presence of the hoop.

      As for the comparison of the paper specifications of the P12 and P12 A-RGB, I really don’t see the technical reason why the static pressure of the P12 at the same speed should be higher by… what, 25%, when at a speed lower by 200 rpm it should be +19%? It makes sense to me the other way round. Of course, a higher static pressure is indirectly caused by the larger hub, if only because it leaves a smaller empty area between the blades. The smaller the fan format, the higher the static pressure per unit of airflow. With the P12 A-RGB, the hoop itself also increases the overall pressure (i.e. static pressure as well) to a certain extent, as I mentioned in the article.

      Anyway, I don’t like to dwell on these things about official parameters. The last thing we want is to have unnecessary back-and-forth with some manufacturer about what they state in their materials. That’s not really the goal, but in this case it couldn’t be completely avoided in the text. Things must always be as clear as possible, that’s what we pride ourselves on. And for the Arctic P12 to have a higher static pressure at the same speed compared to the NF-A12x25, well… 🙂

      Noctua has now reduced the hub size for 140mm LCP fans. From internal communication with their representative we know that it is mainly for better optimization of the Centrifugal Turbulator with the unconventional curvature of the blades. Due to the smaller hub, the part of the blades before the curve (i.e. the typical critical part where aerodynamic efficiency decreases) should catch more air streams.

  2. Would be nice to have the P12 CO variants in there as well as an additional reference.

    I got some P12 Max’s but was disappointed with the overall noise distribution so I returned them (they definitely moved a lot of air but they were considerably noisier across the entire rpm range compared to the P12 CO’s I had, and one was particularly noisy when placed on a radiator – maybe I got a bad early batch).

    I have had regular P12’s before with that hum in the 1000-1100rpm range, but not had a CO variant with that hum before, though obviously limited sample size.

    1. We will add the CO variants, but the closest will be P14 (P14 CO vs. P14), to give a little kick to the building of the 140 mm fan database. We have very few of these in comparison and maybe less than half a year left until the release of Noctua 140mm LCP fans. And of course we want to be adequately prepared for them, i.e. with a sufficiently large reference sample of other fans. But the P12 Max with ball bearings will be added to the tests.

  3. I was able to find the exactly same enhancement from P14s. Unlike the original P14, P14 ARGB has very weak resonant noise at some RPM points and no RPM range that generates a tonal peak. Also the overall noise profile is much better than P14.

    As you mentioned, I also think Arctic’s solution is very cost-efficient way to resolve the unintended vibration of impeller. Everyone knows that the better way is using LCP material, but then the price and difficulties of manufacturing becomes the main problem.

    Although there are some small downsides of this solution(i.e. Increased a moment of inertia of a rotor and slightly smaller area of blades.), I hope the company apply a rotor frame to other models such as P12/P14 PWM PST.