Arctic P12 PWM PST A-RGB: Hoop? Anti-rumble rescue

The biggest shortcoming of Arctic’s original P-series fans is the rumbling sound profile. The manufacturer realized this and decided to do something about it. Sensibly, by implementing a hoop to eliminate the critical vibrations that are the source of the annoying acoustic profile. The implementation turned out well, and already the P12 A-RGB shows how much quieter it is compared to the older P12 model. And the list of improvements doesn’t end there.

Results: Power draw incl. LEDs







Results: Power draw w/o LEDs







Motor power

Why is there a missing value sometimes? There may be more reasons. Usually it is because the fan could not be adjusted to the target noise level. Some have a higher minimum speed (or the speed is low, but the motor is too noisy) or it is a slower fan that will not reach the higher decibels. But the results in the graphs are also missing if the rotor is brushing against the nylon filter mesh. In that case, we evaluate this combination as incompatible. And zero in the graphs is naturally also in situations where we measure 0.00. This is a common occurrence at extremely low speeds with obstructions or within vibration measurements.


Contents

Cooling Topics at HWCooling Techtour ‘26 Belonged to DeepCool

Do you know how a heatpipe works? A DeepCool representative, in a talk at HWCooling Techtour ‘26, looked under the hood. In other words, he explained much of what often remains hidden. This included how they approach development and what they work on internally. That, too, was part of the program, which you can watch. The physical samples, which were also on display, come only at the very end of the whole journey. Read more “Cooling Topics at HWCooling Techtour ‘26 Belonged to DeepCool” »

Contents

Fan frame daisy-chaining trend. When is it (not) helpful

Easier installation? Yes, that’s why it’s done. Daisy-chaining fans using contacts in their frames is great, but it often also comes with pitfalls that reduce “cooling efficiency”. Manufacturers deal with this in different ways. One does it technically one way, another differently. In any case, they know that a frame that is too thick means less space for the blades. And that does not improve airflow per unit of noise. Read more “Fan frame daisy-chaining trend. When is it (not) helpful” »

Contents

Arctic BioniX P14 A-RGB: Elegant daisy chaining is just the beginning

High cooling efficiency is the foundation, but with the BioniX P14 A-RGB fans, Arctic has also made efforts on other fronts. In addition to the clever daisy-chaining method (with the aim of reducing cabling to a minimum), this includes, for example, illumination as intense as possible. The light is guided not only through the entire impeller, but also through the surface of the frame, from the side. There are light guides in these areas as well. Read more “Arctic BioniX P14 A-RGB: Elegant daisy chaining is just the beginning” »

Contents

Comments (5) Add comment

  1. This is a good study of the effect of rings. The blades are a bit shorter so there’s less airflow at the same noise level (despite higher static pressure), but it suppresses blade vibrations very effectively, improving the noise profile for fans using flexible blades.

    I am thinking that the increased static pressure may be partially be due to the increased hub size. It was mentioned by Noctua that the inner parts of the blades have less efficiency, and may even allow air to flow back, so an increased hub size may actually contribute to better static pressure. I think the Gentle Typhoon-like fans all have very similar, large motor hub size because of this.

    It’s also interesting to see that the official static pressure spec vs. the one you measured varies by so much between the P12 and the P12 ARGB. The official spec has the P12 having higher static pressure being higher than the ARGB version, yet it is opposite here.

    The rotor looks pretty much identical to that of the P12 Max, the other minor difference is the ribs in the stator. Are there any differences apart from blade material and the bearing (aside from RGB?) Perhaps this is the budget fan to get if you want to avoid the dual ball bearing noise of the P12 Max, even if you do not want or need RGB.

    1. Well, the best study would be with P14 rev. 1 vs. rev. 2, if the same motor is used across revisions and the only difference is really in the (non)presence of the hoop.

      As for the comparison of the paper specifications of the P12 and P12 A-RGB, I really don’t see the technical reason why the static pressure of the P12 at the same speed should be higher by… what, 25%, when at a speed lower by 200 rpm it should be +19%? It makes sense to me the other way round. Of course, a higher static pressure is indirectly caused by the larger hub, if only because it leaves a smaller empty area between the blades. The smaller the fan format, the higher the static pressure per unit of airflow. With the P12 A-RGB, the hoop itself also increases the overall pressure (i.e. static pressure as well) to a certain extent, as I mentioned in the article.

      Anyway, I don’t like to dwell on these things about official parameters. The last thing we want is to have unnecessary back-and-forth with some manufacturer about what they state in their materials. That’s not really the goal, but in this case it couldn’t be completely avoided in the text. Things must always be as clear as possible, that’s what we pride ourselves on. And for the Arctic P12 to have a higher static pressure at the same speed compared to the NF-A12x25, well… 🙂

      Noctua has now reduced the hub size for 140mm LCP fans. From internal communication with their representative we know that it is mainly for better optimization of the Centrifugal Turbulator with the unconventional curvature of the blades. Due to the smaller hub, the part of the blades before the curve (i.e. the typical critical part where aerodynamic efficiency decreases) should catch more air streams.

  2. Would be nice to have the P12 CO variants in there as well as an additional reference.

    I got some P12 Max’s but was disappointed with the overall noise distribution so I returned them (they definitely moved a lot of air but they were considerably noisier across the entire rpm range compared to the P12 CO’s I had, and one was particularly noisy when placed on a radiator – maybe I got a bad early batch).

    I have had regular P12’s before with that hum in the 1000-1100rpm range, but not had a CO variant with that hum before, though obviously limited sample size.

    1. We will add the CO variants, but the closest will be P14 (P14 CO vs. P14), to give a little kick to the building of the 140 mm fan database. We have very few of these in comparison and maybe less than half a year left until the release of Noctua 140mm LCP fans. And of course we want to be adequately prepared for them, i.e. with a sufficiently large reference sample of other fans. But the P12 Max with ball bearings will be added to the tests.

  3. I was able to find the exactly same enhancement from P14s. Unlike the original P14, P14 ARGB has very weak resonant noise at some RPM points and no RPM range that generates a tonal peak. Also the overall noise profile is much better than P14.

    As you mentioned, I also think Arctic’s solution is very cost-efficient way to resolve the unintended vibration of impeller. Everyone knows that the better way is using LCP material, but then the price and difficulties of manufacturing becomes the main problem.

    Although there are some small downsides of this solution(i.e. Increased a moment of inertia of a rotor and slightly smaller area of blades.), I hope the company apply a rotor frame to other models such as P12/P14 PWM PST.