FD Aspect 14 RGB PWM: Larger rotor, higher airflow per dBA

Basis of the methodology, the wind tunnel

Starting with the Fractal Design Aspect 14 RGB PWM test, we are starting to build a database of 140mm fan results. These may have a smaller market presence due to poorer compatibility, but compared to the 120mm models they have the makings of higher efficiency, which is why they are more popular among many users. The Aspect 14 RGB PWM fan, in addition to its aerodynamic qualities, also fights for customer favour with its lighting.

The basis of the methodology, the wind tunnel

Before you start reading the methodology with all the details, take a look at the test tunnel as a whole. This is the heart of the whole system, to which other arteries are connected (manometer, vibrometer, powermeter, …). The only solid part of the tunnel from the measuring instruments is the anemometer.

The shape of the wind tunnel is inspired by the Venturi tube, which has long been used to measure the flow of liquids and gasses. The Venturi effect for wind speed measuring is also known from the aerospace industry. However, the design for measuring computer fans has its own specificities, which this proposal of ours reflects.

The individual parameters of the HWC wind tunnel for fan tests are the result of physical simulations and practical debugging. All the details (folds, material or finish used) have a rationale behind them and are designed this way for a specific reason. We will discuss the individual design details in turn in the description of the sub-variable measurements.

Now we will briefly elaborate on some things that do not fit thematically into the text of the following chapters. Namely, for example, that the skeleton of the wind tunnel is the work of a 3D printer (PLA). The rough print was, of course, then thoroughly machined by grinding, fusing, polishing and varnishing. Especially important is the smooth finish of the interior walls.

When joining the individual parts, the emphasis was on making sure that they fit together flawlessly, that they were sealed flawlessly (we will come back to this when we describe the test procedures for pressure measurement), but also that the joints were not loosened by use. Everything is disassemblable for servicing purposes, but it is ensured that the properties are maintained during use and, for example, even under the stress of vibration. The threads are secured with either lock nuts or thread-locking fluid. It depends on which is more suitable in which place.

When the wind tunnel is not in use, it is enclosed in a dust-tight chamber. In addition to the technical equipment and its correct storage, it is also important for objective outputs that all measuring instruments are calibrated according to the standard. Without this, it would be impossible to stand behind your results and rely on the manufacturers’ specifications. Calibration protocols are therefore an important part of the methodology. Testing is carried out at an ambient air temperature of 21–21.3 °C, humidity is approximately 45 % (± 2 %).

Fans come to us for testing in at least two pieces of the same model. If the deviations of any of the measured values are greater than 5 %, we also work with a third or fourth sample and the average value is formed by the results of the fans that came out the most similar and the differences between them fit under 5 %.


  •  
  •  
  •  
Flattr this!

We wrote 7 years ago. Tests you may have overlooked

Some articles become obsolete faster, others are relevant for a long time. Such, more durable ones usually do not focus on a specific product, but on a topic as a whole, with a pinch of generality. Articles like this have always been given space around here, since the beginning of HWCooling, and it probably doesn’t hurt to bring them up again. Well, at least as part of this selection which would be a shame to miss forever. Read more “We wrote 7 years ago. Tests you may have overlooked” »

  •  
  •  
  •  

Noctua on measuring fan noise: Different angles, different results

Noise measurements are an extremely complex topic. Imagine you have ten different sound sources. The noise from each will radiate through the space in different ways, and measuring ‘which is the noisiest’ and coming up with a clear verdict on that is a really hard nut to crack. To give you a better idea, we’ve interviewed Noctua. Different measurement techniques yield potentially different and sometimes contradictory conclusions. Read more “Noctua on measuring fan noise: Different angles, different results” »

  •  
  •  
  •  

Noctua NF-A14x25r on a radiator. Tested with DIY frame

Due to the atypical spacing of the mounting holes for its format, the new Noctua NF-A14x25r G2 PWM fans cannot be installed in 140mm positions as standard. You need a conversion frame for that, and one such frame was designed, made and sent to us by an HWCooling reader. So, we were able to simulate and test one of the most anticipated fans of recent years (NF-A14x25 G2 PWM) already now. Read more “Noctua NF-A14x25r on a radiator. Tested with DIY frame” »

  •  
  •  
  •  

One comment Add comment

Leave a Reply

Your email address will not be published. Required fields are marked *