FD Aspect 14 RGB PWM: Larger rotor, higher airflow per dBA

Static pressure measurement…

Starting with the Fractal Design Aspect 14 RGB PWM test, we are starting to build a database of 140mm fan results. These may have a smaller market presence due to poorer compatibility, but compared to the 120mm models they have the makings of higher efficiency, which is why they are more popular among many users. The Aspect 14 RGB PWM fan, in addition to its aerodynamic qualities, also fights for customer favour with its lighting.

Static pressure measurement…

Finally, it is time to move further down the tunnel a bit. Just behind the fan is a static pressure sensing probe. Its position has been chosen with maximum measurement efficiency in mind. In other words, the sensors are placed at the points of highest pressure (although this is virtually the same everywhere in the unconstrained part of the tunnel).

The Fieldpiece ASP2, which is connected to the Fieldpiece SDMN5 manometer, is used to measure the static pressure in the tunnel. The latter also allows measurements in millimetres of water column, but we measure in millibars. This is a more finely resolved base unit for this meter. And only from there we convert the measured values into mm H2O to allow easy comparison with what the manufacturers state.

Internal part of the probe to measure the static pressure inside the tunnel…

While we wrote when measuring noise levels that our results could not be compared with the parameters, that is no longer the case here. As long as the fan manufacturers do not embellish the parameters, they should quote approximately the same pressure values as our tests show. The most significant deviations can only arise at the level of varying accuracy of the measuring instruments, but these are negligible percentages.

…and the external part leading to the manometer

The greater the difference between the manufacturer’s claimed values and ours, the less the specifications correspond to reality. If the claimed values are significantly higher, it is certainly an intention to artificially give an advantage to the fans on the market. However, if the manufacturer quotes a lower pressure value than we do, it points to something else. Namely, a weaker tightness of the measuring environment. The less tight the tunnel is, the lower the pressure you naturally measure. This is one of the things we tuned for an extremely long time, but in the end we ironed out all the weak spots. Whether it’s the passage for the probe itself, the flanges around the anemometer, even the anemometer frame itself, which is made up of two parts, needed to be sealed in the middle. Finally, the flap at the tunnel outlet must also be perfectly tight. That’s because static pressure has to be measured in zero airflow.

The furthest part from the fan – cap for static pressure measurements

But there is one thing that often lowers the pressure of the fans a bit. And that’s protruding anti-vibration pads in the corners or otherwise protruding corners. In other words, when the fan doesn’t fit perfectly to the mounting frame at the inlet, and there are small gaps around the perimeter, that also affects what you measure. But we have not gone into this because it is already a quality feature of the fan. In the same way, it will “stand out” and perform a bit weaker than it has the potential to do with better workmanship, even after application by the end user.


  •  
  •  
  •  
Flattr this!

Noctua on measuring fan noise: Different angles, different results

Noise measurements are an extremely complex topic. Imagine you have ten different sound sources. The noise from each will radiate through the space in different ways, and measuring ‘which is the noisiest’ and coming up with a clear verdict on that is a really hard nut to crack. To give you a better idea, we’ve interviewed Noctua. Different measurement techniques yield potentially different and sometimes contradictory conclusions. Read more “Noctua on measuring fan noise: Different angles, different results” »

  •  
  •  
  •  

Noctua NF-A14x25r on a radiator. Tested with DIY frame

Due to the atypical spacing of the mounting holes for its format, the new Noctua NF-A14x25r G2 PWM fans cannot be installed in 140mm positions as standard. You need a conversion frame for that, and one such frame was designed, made and sent to us by an HWCooling reader. So, we were able to simulate and test one of the most anticipated fans of recent years (NF-A14x25 G2 PWM) already now. Read more “Noctua NF-A14x25r on a radiator. Tested with DIY frame” »

  •  
  •  
  •  

DeepCool also brings new ARGB fans to Gamescom (2024)

Starting August 21, DeepCool, among others, will be among the vendors at Gamescom 2024. There will be a lot of cooling hardware at their booth that you haven’t been able to come in contact with yet because it’s not sold yet. But now you can come and see live, for example, fans from the FT or FD series (with ARGB LED) and a good attraction is also the Assassin IV VC Vision and many more, still shrouded in a veil of secrecy. Read more “DeepCool also brings new ARGB fans to Gamescom (2024)” »

  •  
  •  
  •  

One comment Add comment

Leave a Reply

Your email address will not be published. Required fields are marked *