Endorfy Stratus 140 PWM: Low price, high efficiency

The cheapest 140mm fan we’ve tested so far beats even significantly more expensive 120mm models at comparable noise levels. That’s because of the use of a larger cross-sectional area, as well as the efficient impeller geometry that the Stratus 140 PWM definitely has. “Cheap” fan doesn’t necessarily mean “weak”, though of course there are some compromises based on more limited manufacturing resources than with more expensive fans.

Results: Frequency response of sound with a radiator

Measurements are performed in the TrueRTA application, which records sound in a range of 240 frequencies in the recorded range of 20–20,000 Hz. For the possibility of comparison across articles, we export the dominant frequency from the low (20–200 Hz), medium (201–2,000 Hz) and high (2,001–20,000 Hz) range to standard bar graphs.

However, for an even more detailed analysis of the sound expression, it is important to perceive the overall shape of the graph and the intensity of all frequencies/tones. If you don’t understand something in the graphs or tables below, you’ll find the answers to all your questions in this article. It explains how to read the measured data below correctly.

The vast majority of fan sound operates in the 70–7000 Hz band. You can virtually ignore frequencies above 7000 Hz, they reflect electromagnetic noise from the measurement chain. This (electromagnetic noise) also extends to frequencies below 70 Hz, although there is still aerodynamic noise at these frequencies. These bands (below 70 Hz and above 7 kHz) could be safely “cut out”, but we do not. Just in case one of the fans does have an anomaly that needs to be controlled and visualized.

Note: For these measurements a thinner radiator of 28 mm is used. Such thickness (and restrictiveness with FPI 22) is common in practice (also within AIO coolers).



Wordpress Table Plugin




Wordpress Table Plugin




Wordpress Table Plugin


Why is there a missing value sometimes? There may be more reasons. Usually it is because the fan could not be adjusted to the target noise level. Some have a higher minimum speed (or the speed is low, but the motor is too noisy) or it is a slower fan that will not reach the higher decibels. But the results in the graphs are also missing if the impeller is brushing against the nylon filter mesh. In that case, we evaluate this combination as incompatible. And zero in the graphs is naturally also in situations where we measure 0.00. This is a common occurrence at extremely low speeds with obstructions or within vibration measurements.


Contents

Comments (2) Add comment

    1. It may or may not be. It will depend on the specific store you are shopping at. Somewhere the Stratus 140 PWM fan may be more expensive (probably especially in the US?), somewhere else it may be a bit cheaper.

Leave a Reply

Your email address will not be published. Required fields are marked *