Big test of 120 mm fans. We known everything about eight of them

Initial warm-up and speed recording

To write that we have something mapped out to the last detail is perhaps too bold, but after proper preparation, few pieces of hardware are as easy to evaluate as fans. Of course, this had to be preceded by long preparations, developing a methodology, but you already know the story. What you don’t know yet is the first fruit, or rather the results of Akasa, SilentiumPC, SilverStone, Xigmatek or more exotic Reeven fans.

Initial warm-up…

Before we even start measuring anything, we let the fans run “idle” for a few minutes after plugging them in. This is because immediately after a cold start the fans reach different parameters than after a certain amount of short-term operation.

Until the operating temperature of the lubricant is stabilized, a typically lower maximum performance is achieved. This is because at lower temperatures the lubricant is denser, which is associated with higher friction. Therefore, the fans do not reach maximum speed immediately, but only after the first few seconds. Before the first measurements, we therefore leave the fans running for at least 300 seconds at 12 V, or 100 % PWM intensity.

…and speed recording

The speed of the fans is monitored using a laser tachometer, which reads the number of revolutions from a reflective sticker on the rotor. For this purpose, we use the UNI-T UT372 device, which also allows real-time averaging of samples. Thus, we do not record the peak value in the graphs, but the average speed value from a 30-second time period.

However, the speed itself is a relatively unimportant parameter that is often given more attention than is appropriate. This is the case even in many fan or cooler tests, where speed is used to normalize the different modes in which other variables are measured.

We monitor the speed of the fans with a laser tachometer

However, hyper-focusing on a specific speed is a rather unfortunate decision if only because the fans don’t gain any commonality. At the same speed all other variables are different, there is no intersection. It can be noted that a better normalization would have been by any other variable, whether it be static pressure, flow or noise level, which wins in our case. But more on that in the next chapter.

We only measure the speed so that you can associate a particular parameter (such as the amount of static pressure or some noise level) with something according to which you can adjust the fan yourself. Perhaps for that alone, the information about the achieved speed is useful. As part of the fan analysis, we will also indicate what the fans’ starting and minimum speeds are. Start-up speeds tend to be higher than minimum speeds because more force is required to get the rotor moving than once the fan rotor is spinning, and a minimum power intensity is sought at which the fan does not stall.


  •  
  •  
  •  
Flattr this!

Retrotest: 8× PC case. From small to “large”

In the archives we found some remarkable tests that have never been published in English. Although they are heavily out of date ( cases included have not been sold for a long time), it illustrates well the possible impact of cooling across a wide variety of designs. And by those we also mean completely passive solutions that use their own shell to dissipate heat, as well as rather larger midi-towers and also something in between. Read more “Retrotest: 8× PC case. From small to “large”” »

  •  
  •  
  •  

In vivo fan tests: 14 models in system positions

Here and there we come across the opinion that it is advisable to test fans in real life conditions, which we can easily refute. At the same time, we understand that a layman can best identify with the differences in component temperatures that arise precisely due to different fan airflows. To help you see the correlations of such tests with results from “unnatural” environments, here’s something we remembered. Read more “In vivo fan tests: 14 models in system positions” »

  •  
  •  
  •  

Akasa Gecko Pro: An SSD cooler with a “different” orientation

The successor to the SSD cooler, which didn’t have much competition in its price range. That’s one way to introduce the Gecko Pro, which is a bit more expensive, but also more refined (in terms of mounting as well). And it also has a distinctive feature that clearly distinguishes it from other coolers – the fins are not longitudinal (as is common), but in width. The price to cooling performance ratio is again excellent. Read more “Akasa Gecko Pro: An SSD cooler with a “different” orientation” »

  •  
  •  
  •  

Comments (2) Add comment

  1. Although the test a super, non of the recommended Fans can be bought today making it intentesting but overal not that usefull. For next test, please include some fans that are expeded to be solf for at least one year later.

    1. The selection of older, outdated fans for this test was purposeful. The goal was to get some results/ some basic idea to have something to go off of when evaluating current fans. When you look at the current database, it overwhelmingly contains fan models that are widely available in stores: https://www.hwcooling.net/en/bequiet-light-wings-bl072-sturdy-rotor-with-argb-leds/13/

      The first eight have been selected so that later on none of these models will lack (since they are no longer sold) an in-depth evaluation of all aspects, as we do at the end of the “solo” tests, of which there are 26 after this article.

Leave a Reply

Your email address will not be published. Required fields are marked *