The end, or just the beginning? 100 fans in HWCooling tests

Our database now includes one hundred fans—75 in the 120 mm format and 25 models with a physical size of 140 mm. In this article, we have compiled all data into unified charts. What was once separated for clarity is now brought together again, and the commentary will also include a… look ahead regarding fan testing. But we can already reveal that there is still a lot more to come.

Everything changes with obstacles

So far, we have described how static pressure and airflow measurements are made under conditions where the fan has no obstacles in its path. In practice, however, fans do not usually blow into an empty space, but have a filter, grille or radiator in front of or behind them, the fins of which need to be pushed through as efficiently as possible.

A set of practical obstacles with which we measure the effect on airflow, static pressure, but also noise

We will also measure both airflow and pressure through practical obstacles for the reasons stated above. These include two types of filters that are usually used in PC cases. One fine – nylon and the other plastic with a thinner mesh. One other obstacle is the hexagonal grille perforated at 50%, on which the vast majority of fans – intake and exhaust – are installed. In some cases, we measure the effect of the obstacles on the results at positions (behind or in front of the impeller) that are used in practice. All obstacles are both pushed through to detect pressure drops, but also pulled through, which in turn speaks to the impact on airflow.

We use two radiators that differ in thickness and fin density. The EK CoolStream SE120/140 is 28 mm thick and the FPI is 22, the Alphacool NexXxoS XT45 v2 is thicker (45 mm) but with less FPI. CoolStream’s fin disposition is also similar in parameters to AIOs. The results on the NexXxoS will again be attractive for those who build their own water cooling loops, where the fans should work well even at low speeds – hence the lower fin density.

These obstacles and especially the radiators, but also the grilles, increase the mechanical resistance in front of the fan, resulting in higher noise levels. However, we will still tune the fan speeds to the specified noise levels of 31 to 45 dBA. Naturally, the speeds will always be lower than when testing without obstacles, but we will maintain the noise levels for clarity. The different noise levels with and without obstacles will only be at maximum power. In this mode it will also be nice to see how the fan design works with the obstacle and in which case the noise level increases more and in which less.

Contents

Adata XPG Vento Pro 120 PWM: Refining the “imperfect”

The Adata Vento Pro PWM fans face a tough challenge ahead. They associate themselves with the legendary Gentle Typhoon D1225C fans, claiming to address the major shortcomings of the older GT models. And you probably know what those are – extremely high vibrations. These should not affect the XPG fans. The aerodynamic design they’re built on is excellent in the best sense of the word, and there’s no need to debate that. Read more “Adata XPG Vento Pro 120 PWM: Refining the “imperfect”” »

Contents

ADATA PCIe 5.0 SSDs introduce low-power controller, unusual cooler

SSDs using the high-speed PCI Express 5.0 interface have faced significant issues with power consumption and overheating since their debut virtually across the board, as all early models featured the same hot-running Phison E26 controller. This is now improving with the arrival of more efficient second-generation modules. Among the first are ADATA’s XPG Mars 980 drives, which benefit from a controller manufactured using a 6nm process. Read more “ADATA PCIe 5.0 SSDs introduce low-power controller, unusual cooler” »

Contents

Adata is not afraid, they gave the XPG Hurricane holey blades

These are truly unconventional fans. While the rotor shapes tend to vary across different models, in different materials, the XPG Hurricane design clearly stands out among the rest. They have sort of dual blades and prominent protrusions and, imagine, some sort of openings as well. Overall, the shape of the blades is more complex and it is not a typical quadrilateral geometry either. How can this possibly work? Read more “Adata is not afraid, they gave the XPG Hurricane holey blades” »

Contents

Comments (4) Add comment

  1. Thank you for all the hard work in reviewing and compiling this information!

    If it’s not too much effort, would it be possible to maintain a page like this going forward with each new reviewed fan added on? It’ll make a convenient location to be able to reference back to (a one-stop-shop if you would).

    1. Thank you for the comment! 🙂

      What exactly do you mean by keeping it the same as in this article?

      We separated the 140 mm fans from the 120 mm ones to prevent the charts from becoming too long. Even as they are now—especially in the 120 mm category, where we have more models—the graphs already take up quite a lot of vertical pixels. If combined, navigating them would be rather inconvenient, even on high-resolution monitors

Leave a Reply

Your email address will not be published. Required fields are marked *