Adata XPG Vento Pro 120 PWM: Refining the “imperfect”

The Adata Vento Pro PWM fans face a tough challenge ahead. They associate themselves with the legendary Gentle Typhoon D1225C fans, claiming to address the major shortcomings of the older GT models. And you probably know what those are – extremely high vibrations. These should not affect the XPG fans. The aerodynamic design they’re built on is excellent in the best sense of the word, and there’s no need to debate that.

… and of airflow

With airflow measurements, we can well explain why the test tunnel is shaped the way it is. It doesn’t consist of two parts just so that the “exhaust” can be conveniently clogged for pressure measurements. The anemometer (i.e. the wind speed measuring instrument) is held together by two parts, two formations, through the flanges.

The front part, at the beginning of which the fan is mounted, becomes steadily narrower and from about two thirds of the way through the cross-section is smaller than that of a 120 mm fan. The reason for this is that the cross-section of the anemometer is always smaller than that of the fans tested. The taper towards the anemometer fan is as smooth as could be chosen and the tunnel walls are smooth. This has minimized the occurrence of unnatural turbulence.

The difference between the cross section at the intake (fan under test) and at the constriction point (anemometer) also means a difference in dynamic pressure, the principles of the Venturi effect apply here. In order to avoid distortion at this level and to ensure that the fan airflow is not different from what it actually is, the Bernoulli equation must be applied to the measured values (for maximum accuracy, the calculation also takes into account the internal cross-sectional area of the anemometer, i.e. its inactive part ). After all this, it is again possible to confront our results with the paper parameters.

We use an Extech AN300 anemometer with a large 100 mm fan for the measurements. Its big advantage over other anemometers is that it is made for bidirectional sensing. This allows tests at different fan orientations. However, the “pull” position is more suitable or accurate for measurements, even though it may not seem so at first glance, but we’ll explain.

Here, we get to the second part of the tunnel, the part behind the anemometer. It is part of the whole device, mainly to allow a laminar flow of air to arrive at the impeller of the anemometer. Otherwise, uncontrolled side whirls would be reflected in the results, which are inconsistent with accurate measurements. Therefore, we will test the flow in the pull position. If anyone would like us to elaborate more on this topic, we can elaborate further at any time in the discussion below the article. Ask away. 🙂

The rear of the tunnel ensures, among other things, that the air supply to the anemometer fan is laminar

In regard to the anemometer, we shall return for a bit to noise measurements and to setting modes according to fixed noise levels. It may have occurred to you as you were reading that the anemometer fan is also a source of sound that needs to be filtered out when measuring fans. For this reason, we insert a securing pad between the frame and the anemometer fan before each measurement and mode setting according to the fixed noise level. This, by the way, also holds the anemometer fan during static pressure measurements.


Contents

ADATA PCIe 5.0 SSDs introduce low-power controller, unusual cooler

SSDs using the high-speed PCI Express 5.0 interface have faced significant issues with power consumption and overheating since their debut virtually across the board, as all early models featured the same hot-running Phison E26 controller. This is now improving with the arrival of more efficient second-generation modules. Among the first are ADATA’s XPG Mars 980 drives, which benefit from a controller manufactured using a 6nm process. Read more “ADATA PCIe 5.0 SSDs introduce low-power controller, unusual cooler” »

Contents

Adata is not afraid, they gave the XPG Hurricane holey blades

These are truly unconventional fans. While the rotor shapes tend to vary across different models, in different materials, the XPG Hurricane design clearly stands out among the rest. They have sort of dual blades and prominent protrusions and, imagine, some sort of openings as well. Overall, the shape of the blades is more complex and it is not a typical quadrilateral geometry either. How can this possibly work? Read more “Adata is not afraid, they gave the XPG Hurricane holey blades” »

Contents

Adata XPG Storm: good looking but not efficient

16,500 rpm is extreme. A tiny fan in the unique SSD cooler by Adata can run at such a speed. We expected that it will be possible to regulate it and choose a reasonable setting, but there is no compromise in this design, and frankly, so many imperfections make it very difficult to see something positive about this product, which is a shame because the “core“ is pretty effective. Read more “Adata XPG Storm: good looking but not efficient” »

Contents

One comment Add comment

  1. Or maybe the Vento Pro 120 PWM deserved the “Top-notch” award? We did consider it, but in the end – given a few compromises and the low official price – we decided differently from an HWCooling editorial standpoint. 🙂

Leave a Reply

Your email address will not be published. Required fields are marked *