Scythe Grand Tornado 120: Even an LCP fan can be “cheap”

We were very excited to see the results of the Grand Tornado 120. It looks good geometrically and is also one of the cheapest LCP models out there. Scythe has also informed us that the Grand Tornado 120 is set to outperform the legendary Gentle Typhoon (D1225C). And it’s true, it does outperform it, though perhaps in different ways than you’d expect. But the LCP fan from Scythe gets along really well with radiators.

Basis of the methodology, the wind tunnel

Before you start reading the methodology with all the details, take a look at the test tunnel as a whole. This is the heart of the whole system, to which other arteries are connected (manometer, vibrometer, powermeter, …). The only solid part of the tunnel from the measuring instruments is the anemometer.

The shape of the wind tunnel is inspired by the Venturi tube, which has long been used to measure the flow of liquids and gasses. The Venturi effect for wind speed measuring is also known from the aerospace industry. However, the design for measuring computer fans has its own specificities, which this proposal of ours reflects.

The individual parameters of the HWC wind tunnel for fan tests are the result of physical simulations and practical debugging. All the details (folds, material or finish used) have a rationale behind them and are designed this way for a specific reason. We will discuss the individual design details in turn in the description of the sub-variable measurements.

Now we will briefly elaborate on some things that do not fit thematically into the text of the following chapters. Namely, for example, that the skeleton of the wind tunnel is the work of a 3D printer (PLA). The rough print was, of course, then thoroughly machined by grinding, fusing, polishing and varnishing. Especially important is the smooth finish of the interior walls.

When joining the individual parts, the emphasis was on making sure that they fit together flawlessly, that they were sealed flawlessly (we will come back to this when we describe the test procedures for pressure measurement), but also that the joints were not loosened by use. Everything is disassemblable for servicing purposes, but it is ensured that the properties are maintained during use and, for example, even under the stress of vibration. The threads are secured with either lock nuts or thread-locking fluid. It depends on which is more suitable in which place.

When the wind tunnel is not in use, it is enclosed in a dust-tight chamber. In addition to the technical equipment and its correct storage, it is also important for objective outputs that all measuring instruments are calibrated according to the standard. Without this, it would be impossible to stand behind your results and rely on the manufacturers’ specifications. Calibration protocols are therefore an important part of the methodology. Testing is carried out at an ambient air temperature of 21–21.3 °C, humidity is approximately 45 % (± 2 %).

Fans come to us for testing in at least two pieces of the same model. If the deviations of any of the measured values are greater than 5 %, we also work with a third or fourth sample and the average value is formed by the results of the fans that came out the most similar and the differences between them fit under 5 %.


Contents

Asus TUF RTX 5070 Ti Deshroud: Dual 140 mm Arctic P14 Slim Fans

The TUF GeForce RTX 5070 Ti has a heatsink large enough to mount 140 mm fans. Swapping them is easy: remove a few screws and lift off the shroud with stock fans without breaking the warranty seal. We’ll use that to try a niche option—the low-profile 140 mm Arctic P14 Slim PWM PST. The card gets wider but keeps a reasonable height and, at similar temperatures, runs way quieter. Read more “Asus TUF RTX 5070 Ti Deshroud: Dual 140 mm Arctic P14 Slim Fans” »

Contents

Details of the Noctua NF-A14x25r G2 PWM fan + minitest

Close up of the new Noctua NF-A14x25r G2 PWM fan and its first tests. However, consider these as material for a “rough idea”, since as you already know, the pilot 140 mm LCP fans have atypical mounting holes for their format, so their mounting to the wind tunnel was necessarily non-standard. However, a few things can be concluded from these partial measurements as well. Read more “Details of the Noctua NF-A14x25r G2 PWM fan + minitest” »

Contents

Thermaltake: Rotate a fan? Nah, replace the rotor!

Just when it seems that the pointlessness of some things must have gone through the roof, along comes SWAFAN 12/14 RGB. We can’t put it any other way, Thermaltake is taking advantage of the fact that casual users don’t know how a fan works. After all, paying for two rotors is a better “bargain” than having to orient one as you need it. At least if they didn’t have the same performance characteristics… That’s not how elite companies are built. Read more “Thermaltake: Rotate a fan? Nah, replace the rotor!” »

Contents

Comments (4) Add comment

  1. DNF at the very high target of 31dB(A) means it isn’t cheap, it means no matter the price it’s too expensive
    additionally knowing it starts at around 680RPM and it still doesn’t pass that target means it’s just bad acoustically
    it may find a niche, people are frequently mentioning this or that dethroning Noctua while the performance is only slightly higher at one very specific and extremely high noise target so at some point it may be a decent option, but I just wouldn’t bother, no reason to stand that noise when I can just set A12x25 a tiny bit below this ones starting speed and have it perform better and stay silent

    1. This is subjective. It depends on who is looking for what. If the priority is the highest possible airflow regardless of noise level, while also weighing low vibration or extra durability, then the Grand Tornado 120 can be a great choice. In the context of that potentially high durability (if Scythe doesn’t exaggerate the MTBF value…), we also discussed the server concept of the Scythe Grand Tornado 120 fan in the discussion below the text in another language…

      1. for separate-room-home-server I’d likely go with Noctua PPC or T30 (or NH-P1 due to superior reliability if the heat load was lower, though AC has the advantage of providing a decent heatsink that will prevent your system from shutting down even if fans stop, LC on the other hand…), for regular server room with regular server fans like Delta
        for living/working space silence is a requirement impossible to give up on so the silent performance is all that matters

Leave a Reply

Your email address will not be published. Required fields are marked *