Asus ProArt PF120: The most efficient fan at low noise level

It wants to go head‑to‑head with the Phanteks T30-120 fan, while also having a slight edge in every respect. That’s Asus’s marketing—and now comes reality in HWCooling’s in‑depth analysis. The ProArt PF120 fans are truly something exceptional and worth paying attention to. High cooling efficiency and elegant daisy‑chaining are just the beginning. The overall design of Asus’s fans is impressive.

Base 6 equal noise levels…

There are several options by which to normalize the test modes for fans. In the previous chapter, we wrote that perhaps the least appropriate option is equal speed.

Settings according to the same static pressure or flow are for consideration, but we find it most sensible in the long term to normalize the measurement modes according to the same noise levels. Firstly because decibels are a logarithmic unit and all others scale linearly, but mainly because you can orientate fastest by the same noise levels. The easiest way to compare the efficiency of fans is just by how they perform at the same sound pressure level. Of all the options, this is the one that most people can best imagine and bounce off of when considering other variables.

The individual noise level modes are adjusted from low levels continuously to higher levels. All users will find their results in the tests, regardless of whether they prefer very quiet operation at the limit of audibility or whether high performance is paramount.

The quietest mode corresponds to 31 dBA, followed by 33 dBA, and for each additional mode we add 3 dBA, which always doubles the noise level (36, 39, 42 and 45 dBA). Finally, we measure the fans at maximum power. Here, each one already has a slightly different noise level, which we also report. If there are missing measurements between the results for any of the fans, this means that it was not possible to set the target noise level. Either because its minimum speed exceeds the quietest mode of 31 dBA or vice versa because the fan is quieter than 45 dBA at maximum power.

It is important to add that our noise level measurements are incomparable to the values quoted by the fan manufacturers in their specifications. One of the reasons is because we use a parabola-shaped collar around the sensor of the noise meter, which increases sensitivity. This is important in order to distinguish and set to the same noise level even modes at very low speeds, especially 31 dBA.

The noise meter next to the fan is quite close for sufficient resolution. The distance between the frame and the sensor is 15 centimeters. The sensor is positioned in such a way that there is no distortion or that the noise level measurements are not affected by airflow. Therefore, the noise meter is centered perpendicularly to the frame that defines the depth of the fan. Everything is always at the same angle and at the same distance. We use an inclinometer and markers to set the distances precisely and always the same.

The noise meter sensor is positioned relative to the position of the fan from the profile. It is centered to the depth of the frame both vertically and horizontally

We use a Reed R8080 noise meter to measure noise levels. This allows real-time averaging of samples, which is important for fine-tuning individual modes. We tune the fans until the specified noise level is reached to two decimal places, for example 31.50 dBA. The noise meter is the only instrument we calibrate inside our testlab. The other instruments have been calibrated by the relevant technical institutes. However, in the case of the noise meter, calibration is required before each test and we therefore have our own calibrator. This is already calibrated externally according to the standard.


Contents

The end, or just the beginning? 100 fans in HWCooling tests

Our database now includes one hundred fans—75 in the 120 mm format and 25 models with a physical size of 140 mm. In this article, we have compiled all data into unified charts. What was once separated for clarity is now brought together again, and the commentary will also include a… look ahead regarding fan testing. But we can already reveal that there is still a lot more to come. Read more “The end, or just the beginning? 100 fans in HWCooling tests” »

Contents

Prime GeForce RTX 5070 Deshroud With Arctic P12 Pro A-RGB

Asus cards such as the Prime GeForce RTX 5070 allow easy removal of the shroud with the fans, without removing the heatsink itself. This opens room for experimentation with cooling.We will find out how much you can gain by replacing stock fans with a pair of 120mm Arctic P12 Pro A-RGB fans. We will measure operating characteristics from 20 to 100% fan speed and see how much the card’s noise level drops at identical temperatures. Read more “Prime GeForce RTX 5070 Deshroud With Arctic P12 Pro A-RGB” »

Contents

Asus Prime GeForce RTX 5070 with 3× Arctic P9 PWM PST Deshroud

Alongside our previous tests of premium 92 mm Noctua fans, we’re adding something for value-focused users. For the more affordable Prime-series card, these are a better match. We’ll measure how much quieter the card gets after swapping the stock fans for budget 92 mm Arctic P9 PWM PST models with sleeve bearings, and compare the noise to the Arctic P9 PWM PST CO variant with dual ball bearings for continuous operation. Read more “Asus Prime GeForce RTX 5070 with 3× Arctic P9 PWM PST Deshroud” »

Contents

Leave a Reply

Your email address will not be published. Required fields are marked *