Asus ProArt PF120: The most efficient fan at low noise level

It wants to go head‑to‑head with the Phanteks T30-120 fan, while also having a slight edge in every respect. That’s Asus’s marketing—and now comes reality in HWCooling’s in‑depth analysis. The ProArt PF120 fans are truly something exceptional and worth paying attention to. High cooling efficiency and elegant daisy‑chaining are just the beginning. The overall design of Asus’s fans is impressive.

Measurement of static pressure…

Finally, it is time to move further down the tunnel a bit. Just behind the fan is a static pressure sensing probe. Its position has been chosen with maximum measurement efficiency in mind. In other words, the sensors are placed at the points of highest pressure (although this is virtually the same everywhere in the unconstrained part of the tunnel).

The Fieldpiece ASP2, which is connected to the Fieldpiece SDMN5 manometer, is used to measure the static pressure in the tunnel. The latter also allows measurements in millimetres of water column, but we measure in millibars. This is a more finely resolved base unit for this meter. And only from there we convert the measured values into mm H2O to allow easy comparison with what the manufacturers state.

Internal part of the probe to measure the static pressure inside the tunnel…

While we wrote when measuring noise levels that our results could not be compared with the parameters, that is no longer the case here. As long as the fan manufacturers do not embellish the parameters, they should quote approximately the same pressure values as our tests show. The most significant deviations can only arise at the level of varying accuracy of the measuring instruments, but these are negligible percentages.

…and the external part leading to the manometer

The greater the difference between the manufacturer’s claimed values and ours, the less the specifications correspond to reality. If the claimed values are significantly higher, it is certainly an intention to artificially give an advantage to the fans on the market. However, if the manufacturer quotes a lower pressure value than we do, it points to something else. Namely, a weaker tightness of the measuring environment. The less tight the tunnel is, the lower the pressure you naturally measure. This is one of the things we tuned for an extremely long time, but in the end we ironed out all the weak spots. Whether it’s the passage for the probe itself, the flanges around the anemometer, even the anemometer frame itself, which is made up of two parts, needed to be sealed in the middle. Finally, the flap at the tunnel outlet must also be perfectly tight. That’s because static pressure has to be measured in zero airflow.

The furthest part from the fan—cap for static pressure measurements

But there is one thing that often lowers the pressure of the fans a bit. And that’s protruding anti-vibration pads in the corners or otherwise protruding corners. In other words, when the fan doesn’t fit perfectly to the mounting frame at the inlet, and there are small gaps around the perimeter, that also affects what you measure. But we have not gone into this because it is already a quality feature of the fan. In the same way, it will “stand out” and perform a bit weaker than it has the potential to do with better workmanship, even after application by the end user.


Contents

The end, or just the beginning? 100 fans in HWCooling tests

Our database now includes one hundred fans—75 in the 120 mm format and 25 models with a physical size of 140 mm. In this article, we have compiled all data into unified charts. What was once separated for clarity is now brought together again, and the commentary will also include a… look ahead regarding fan testing. But we can already reveal that there is still a lot more to come. Read more “The end, or just the beginning? 100 fans in HWCooling tests” »

Contents

Prime GeForce RTX 5070 Deshroud With Arctic P12 Pro A-RGB

Asus cards such as the Prime GeForce RTX 5070 allow easy removal of the shroud with the fans, without removing the heatsink itself. This opens room for experimentation with cooling.We will find out how much you can gain by replacing stock fans with a pair of 120mm Arctic P12 Pro A-RGB fans. We will measure operating characteristics from 20 to 100% fan speed and see how much the card’s noise level drops at identical temperatures. Read more “Prime GeForce RTX 5070 Deshroud With Arctic P12 Pro A-RGB” »

Contents

Asus Prime GeForce RTX 5070 with 3× Arctic P9 PWM PST Deshroud

Alongside our previous tests of premium 92 mm Noctua fans, we’re adding something for value-focused users. For the more affordable Prime-series card, these are a better match. We’ll measure how much quieter the card gets after swapping the stock fans for budget 92 mm Arctic P9 PWM PST models with sleeve bearings, and compare the noise to the Arctic P9 PWM PST CO variant with dual ball bearings for continuous operation. Read more “Asus Prime GeForce RTX 5070 with 3× Arctic P9 PWM PST Deshroud” »

Contents

Leave a Reply