Asus ProArt PF120: The most efficient fan at low noise level

It wants to go head‑to‑head with the Phanteks T30-120 fan, while also having a slight edge in every respect. That’s Asus’s marketing—and now comes reality in HWCooling’s in‑depth analysis. The ProArt PF120 fans are truly something exceptional and worth paying attention to. High cooling efficiency and elegant daisy‑chaining are just the beginning. The overall design of Asus’s fans is impressive.

… and of airflow

With airflow measurements, we can well explain why the test tunnel is shaped the way it is. It doesn’t consist of two parts just so that the “exhaust” can be conveniently clogged for pressure measurements. The anemometer (i.e. the wind speed measuring instrument) is held together by two parts, two formations, through the flanges.

The front part, at the beginning of which the fan is mounted, becomes steadily narrower and from about two thirds of the way through the cross-section is smaller than that of a 120 mm fan. The reason for this is that the cross-section of the anemometer is always smaller than that of the fans tested. The taper towards the anemometer fan is as smooth as could be chosen and the tunnel walls are smooth. This has minimized the occurrence of unnatural turbulence.

The difference between the cross section at the intake (fan under test) and at the constriction point (anemometer) also means a difference in dynamic pressure, the principles of the Venturi effect apply here. In order to avoid distortion at this level and to ensure that the fan airflow is not different from what it actually is, the Bernoulli equation must be applied to the measured values (for maximum accuracy, the calculation also takes into account the internal cross-sectional area of the anemometer, i.e. its inactive part ). After all this, it is again possible to confront our results with the paper parameters.

We use an Extech AN300 anemometer with a large 100 mm fan for the measurements. Its big advantage over other anemometers is that it is made for bidirectional sensing. This allows tests at different fan orientations. However, the “pull” position is more suitable or accurate for measurements, even though it may not seem so at first glance, but we’ll explain.

Here, we get to the second part of the tunnel, the part behind the anemometer. It is part of the whole device, mainly to allow a laminar flow of air to arrive at the impeller of the anemometer. Otherwise, uncontrolled side whirls would be reflected in the results, which are inconsistent with accurate measurements. Therefore, we will test the flow in the pull position. If anyone would like us to elaborate more on this topic, we can elaborate further at any time in the discussion below the article. Ask away. 🙂

The rear of the tunnel ensures, among other things, that the air supply to the anemometer fan is laminar

In regard to the anemometer, we shall return for a bit to noise measurements and to setting modes according to fixed noise levels. It may have occurred to you as you were reading that the anemometer fan is also a source of sound that needs to be filtered out when measuring fans. For this reason, we insert a securing pad between the frame and the anemometer fan before each measurement and mode setting according to the fixed noise level. This, by the way, also holds the anemometer fan during static pressure measurements.


Contents

The end, or just the beginning? 100 fans in HWCooling tests

Our database now includes one hundred fans—75 in the 120 mm format and 25 models with a physical size of 140 mm. In this article, we have compiled all data into unified charts. What was once separated for clarity is now brought together again, and the commentary will also include a… look ahead regarding fan testing. But we can already reveal that there is still a lot more to come. Read more “The end, or just the beginning? 100 fans in HWCooling tests” »

Contents

Prime GeForce RTX 5070 Deshroud With Arctic P12 Pro A-RGB

Asus cards such as the Prime GeForce RTX 5070 allow easy removal of the shroud with the fans, without removing the heatsink itself. This opens room for experimentation with cooling.We will find out how much you can gain by replacing stock fans with a pair of 120mm Arctic P12 Pro A-RGB fans. We will measure operating characteristics from 20 to 100% fan speed and see how much the card’s noise level drops at identical temperatures. Read more “Prime GeForce RTX 5070 Deshroud With Arctic P12 Pro A-RGB” »

Contents

Asus Prime GeForce RTX 5070 with 3× Arctic P9 PWM PST Deshroud

Alongside our previous tests of premium 92 mm Noctua fans, we’re adding something for value-focused users. For the more affordable Prime-series card, these are a better match. We’ll measure how much quieter the card gets after swapping the stock fans for budget 92 mm Arctic P9 PWM PST models with sleeve bearings, and compare the noise to the Arctic P9 PWM PST CO variant with dual ball bearings for continuous operation. Read more “Asus Prime GeForce RTX 5070 with 3× Arctic P9 PWM PST Deshroud” »

Contents

Leave a Reply

Your email address will not be published. Required fields are marked *