Arctic P14 PWM PST CO or ball vs. fluid bearings

Longer life in exchange for more noise? These are also some of the agenda items we’ll cover in our comparison of the Arctic P14 CO fan with the fluid bearing variant. These are actually the main points. In any case, the ball bearings in the more expensive variant of these fans also have specific features that can be easily observed and distinguished even in normal, “home” use.

Static pressure per euro

Explanatory note: The following charts will give a quick overview of the amount of static pressure per price unit. We can thus talk about the coefficient for the price/performance ratio. This is the ratio of the measured static pressure in mm H2O to the price of the fan (in euros) multiplied by 1000. This is specifically so that the results do not start with unflattering zeros.







Why is there a missing value sometimes? There may be more reasons. Usually it is because the fan could not be adjusted to the target noise level. Some have a higher minimum speed (or the speed is low, but the motor is too noisy) or it is a slower fan that will not reach the higher decibels. But the results in the graphs are also missing if the impeller is brushing against the nylon filter mesh. In that case, we evaluate this combination as incompatible. And zero in the graphs is naturally also in situations where we measure 0.00. This is a common occurrence at extremely low speeds with obstructions or within vibration measurements.


Contents

Arctic BioniX P12 A-RGB: Efficient, inexpensive, illuminated and…

And with very clever daisy‑chaining from one fan to the next. This is what can fill in the ellipsis in the headline. The aerodynamic efficiency remains top‑tier, built on a design that Arctic revised some time ago (with the P12 Pro fans), but which can still be considered “new.” The BioniX P12 A‑RGB fans certainly are (new), and in this in‑depth analysis we focus on how they work. Read more “Arctic BioniX P12 A-RGB: Efficient, inexpensive, illuminated and…” »

Contents

Need new PC fans? Win a three-pack of Arctic P14 Pro A-RGB fans

A fan giveaway is finally here—and there are three of them up for grabs (a three-pack), with exceptionally attractive key characteristics. These are also illuminated variants, which may appeal to some users. Those who are less fond of RGB LED lighting can simply leave it disconnected and keep the fans in the dark. Well, relatively speaking, given that you are competing for the bright (white) version of the Arctic P14 Pro A-RGB fans. Read more “Need new PC fans? Win a three-pack of Arctic P14 Pro A-RGB fans” »

Contents

BioniX (P) now with seven blades, smarter daisy-chaining

Arctic’s new BioniX fans, which adopt a seven-blade geometry, just like the “base” P1x A-RGB models, are nearing release. Based on the results of the older BioniX “P” fans, it can be assumed that aerodynamic efficiency will be higher this time. Alongside the fans, Arctic is also preparing a fan hub to which they can be connected. The method of daisy-chaining one fan to the next is innovative as well. Read more “BioniX (P) now with seven blades, smarter daisy-chaining” »

Contents

Comments (6) Add comment

  1. Expected results, but still an interesting showcase of the effect of only changing the bearings.

    So, the “hum” is still here all the same, despite some claims that the CO version fixes it. ThermalLeft has documented sound differences between revisions too (https://www.youtube.com/watch?v=nt8Ao4GDmzY), but even Arctic themselves doesn’t think revisions will have such an effect. I am starting to think it’s possibly a batch “issue” that may have introduced different properties to the rotor material.

    1. I guess those claims of the CO rumbling less will never come from an official source (from Arctic)? They don’t seem to list among the changes across the revisions the modifications that address this. And personally, I don’t even see the technical reason behind the CO variant or the higher P14 revision (2 vs. 4) being quieter on lower frequencies. The impeller seems to have the same parameters in terms of geometry or material used. Nevertheless, there can certainly be a situation where different noise levels are measured across different fans. But it may not be due to different revisions, and perhaps it may be possible to observe this across different fan pieces of the same revision due to different manufacturing tolerances (which are high in the low-end after all)?

      An analysis that tracks the tonal peaks of multiple pieces from the same revisions on each side would shed more light on this. From our experience, we note that the shape of the spectrograms of multiple pieces of the P14 PWM PST rev. 4 compared to P14 PWM PST CO rev. 3 in the low frequency band is identical at the same speed. The small differences in the spectrograms that you see in the tests are mainly just due to the fact that in modes normalized by the same noise levels, the speeds of the two variants (P14 and P14 CO fans) are slightly different. For the CO, the speeds are always set a little lower due to the noisier bearings.

      1. Perhaps what is known as “resonance” is something else that’s not the frequency spike at ~100 Hz. Namely, the sudden increase in noise at specific RPM ranges. Or, perhaps the two issues are lumped together when people talk about it, when in fact the two (sound profile with pronounced low frequency peak, and some RPM ranges being suddenly louder) are different issues (that perhaps are related).

        I am sure you would have noticed and mentioned it though, when you’re testing the fans and adjusting the fan speeds again and again.

  2. Good day,
    can the testers please answer this?

    So P12 Max, P14 Max have both the better FDB, and only the CO versions have the ball bearing?
    For both black and white version of the P12/14 Max?

    Thanks

    1. When the Max debuted (black color), it had a DBB. Later when the white version came, it had an FDB. Then they switched both models to FDB. The only Arctic fans that have a DBB nowadays are the “CO“ (continuous operation) and all server-grade fans (starting with the letter “S”)
      DBB is optimal in harsh environments (higher temperature) and for continuous operation.
      (I hope you don’t mind that I’m not a reviewer) 😉