Arctic P12 Max: Five blades pushed to the limit

Before Arctic transitions to its new, 7-blade fan design, let’s take a closer look at the one that has characterized the company for many years. And even though the 5-blade fans of the “P” series had certain shortcomings, they demonstrated just how efficient even low-cost designs can be. In the case of high-speed models, such as the tested P12 Max, they also show how far cooling performance can be pushed.

… and of airflow

With airflow measurements, we can well explain why the test tunnel is shaped the way it is. It doesn’t consist of two parts just so that the “exhaust” can be conveniently clogged for pressure measurements. The anemometer (i.e. the wind speed measuring instrument) is held together by two parts, two formations, through the flanges.

The front part, at the beginning of which the fan is mounted, becomes steadily narrower and from about two thirds of the way through the cross-section is smaller than that of a 120 mm fan. The reason for this is that the cross-section of the anemometer is always smaller than that of the fans tested. The taper towards the anemometer fan is as smooth as could be chosen and the tunnel walls are smooth. This has minimized the occurrence of unnatural turbulence.

The difference between the cross section at the intake (fan under test) and at the constriction point (anemometer) also means a difference in dynamic pressure, the principles of the Venturi effect apply here. In order to avoid distortion at this level and to ensure that the fan airflow is not different from what it actually is, the Bernoulli equation must be applied to the measured values (for maximum accuracy, the calculation also takes into account the internal cross-sectional area of the anemometer, i.e. its inactive part ). After all this, it is again possible to confront our results with the paper parameters.

We use an Extech AN300 anemometer with a large 100 mm fan for the measurements. Its big advantage over other anemometers is that it is made for bidirectional sensing. This allows tests at different fan orientations. However, the “pull” position is more suitable or accurate for measurements, even though it may not seem so at first glance, but we’ll explain.

Here, we get to the second part of the tunnel, the part behind the anemometer. It is part of the whole device, mainly to allow a laminar flow of air to arrive at the impeller of the anemometer. Otherwise, uncontrolled side whirls would be reflected in the results, which are inconsistent with accurate measurements. Therefore, we will test the flow in the pull position. If anyone would like us to elaborate more on this topic, we can elaborate further at any time in the discussion below the article. Ask away. 🙂

The rear of the tunnel ensures, among other things, that the air supply to the anemometer fan is laminar

In regard to the anemometer, we shall return for a bit to noise measurements and to setting modes according to fixed noise levels. It may have occurred to you as you were reading that the anemometer fan is also a source of sound that needs to be filtered out when measuring fans. For this reason, we insert a securing pad between the frame and the anemometer fan before each measurement and mode setting according to the fixed noise level. This, by the way, also holds the anemometer fan during static pressure measurements.


Contents

Arctic BioniX P14 A-RGB: Elegant daisy chaining is just the beginning

High cooling efficiency is the foundation, but with the BioniX P14 A-RGB fans, Arctic has also made efforts on other fronts. In addition to the clever daisy-chaining method (with the aim of reducing cabling to a minimum), this includes, for example, illumination as intense as possible. The light is guided not only through the entire impeller, but also through the surface of the frame, from the side. There are light guides in these areas as well. Read more “Arctic BioniX P14 A-RGB: Elegant daisy chaining is just the beginning” »

Contents

Arctic BioniX P12 A-RGB: Efficient, inexpensive, illuminated and…

And with very clever daisy‑chaining from one fan to the next. This is what can fill in the ellipsis in the headline. The aerodynamic efficiency remains top‑tier, built on a design that Arctic revised some time ago (with the P12 Pro fans), but which can still be considered “new.” The BioniX P12 A‑RGB fans certainly are (new), and in this in‑depth analysis we focus on how they work. Read more “Arctic BioniX P12 A-RGB: Efficient, inexpensive, illuminated and…” »

Contents

Need new PC fans? Win a three-pack of Arctic P14 Pro A-RGB fans

A fan giveaway is finally here—and there are three of them up for grabs (a three-pack), with exceptionally attractive key characteristics. These are also illuminated variants, which may appeal to some users. Those who are less fond of RGB LED lighting can simply leave it disconnected and keep the fans in the dark. Well, relatively speaking, given that you are competing for the bright (white) version of the Arctic P14 Pro A-RGB fans. Read more “Need new PC fans? Win a three-pack of Arctic P14 Pro A-RGB fans” »

Contents

Comments (6) Add comment

  1. Overall quite similar behaviour (at same noise levels) vs the ARGB variant. Not too much compromise at lower speeds unlike the P14 Max, which is good to see.

    One thing I just noticed is the different stator ribs compared to other fans in the Arctic P family. Now they’re thicker and straight (like many other fans) rather than thin and curved. This perhaps sacrifices a tiny amount of airflow but is needed for supporting the higher RPM and rotor weight.

    1. Good point. The P12 Max fan is about 20 grams heavier than the P12 A-RGB. And it doesn’t even have any LEDs, which also add some weight. While we don’t know the exact difference in material density – since the P12 Max uses PBT for its rotor and the P12 A-RGB likely uses polycarbonate – there’s definitely some variation happening at that level too. 🙂

      1. it seems the spam filter worked better with the older version… the Indonesian university bot seems pretty persistent (that’s the 3rd time I’ve noticed it) 😉
        … I’m attaching the response to this thread so you don’t have a problem deleting it

        1. so now, I’m really curious if there will be any answer 😀
          …now you chose a different approach instead of deleting… we’ll see 😉

    1. Is there any other information you’re interested in? Let us know, and we’ll do our best to provide whatever is within our capabilities. 🙂

Leave a Reply

Your email address will not be published. Required fields are marked *