Gigabyte Aorus 120 ARGB: Not just stylish, but a proper fan

Measuring the intensity (and power draw) of lighting

To write that we have something mapped out to the last detail is perhaps too bold, but after proper preparation, few pieces of hardware are as easy to evaluate as fans. Of course, this had to be preceded by long preparations, developing a methodology, but you already know the story. What you don’t know yet is the first fruit, or rather the results of Akasa, SilentiumPC, SilverStone, Xigmatek or more exotic Reeven fans.

Measuring the intensity (and power draw) of lighting

Modern fans often include lighting. This is no longer a “cooling” parameter, but for some users the presence of (A)RGB LEDs is important. Therefore, we also measure how intense this lighting is in our tests. These tests are the only ones that take place externally, outside the wind tunnel.
We record the luminosity of the fans in a chamber with reflective walls. This internal arrangement is important to increase the resolution for us to measure anything at all with lower luminosity fans. But also so that the readings do not blend together and it is obvious which fan is emitting more light and which one less.

Fan in the light chamber to measure the intensity of (A)RGB LEDs

The illumination intensity is measured in the horizontal position of the fan, above which is the lux meter sensor (UNI-T UT383S). This is centered on the illumination intensity sensing chamber.
The illumination is controlled via an IR controller and the hue is set to RGB level 255, 255, 255 (white). We record the brightness at maximum and minimum intensity. According to this, you can easily see if the brightness is high enough, but conversely also if the lower level is low enough for you.

In addition to the brightness intensity, we also measure the power draw that it requires. This is again through the shunt, which is between the Gophert CPS-3205 power supply and the (A)RGB LED driver. After this we get a reading of the lighting power draw. In the graphs we show it separately, but also in sum with the motor power draw as the total maximum fan power.


  •  
  •  
  •  
Flattr this!

We wrote 7 years ago. Tests you may have overlooked

Some articles become obsolete faster, others are relevant for a long time. Such, more durable ones usually do not focus on a specific product, but on a topic as a whole, with a pinch of generality. Articles like this have always been given space around here, since the beginning of HWCooling, and it probably doesn’t hurt to bring them up again. Well, at least as part of this selection which would be a shame to miss forever. Read more “We wrote 7 years ago. Tests you may have overlooked” »

  •  
  •  
  •  

Noctua on measuring fan noise: Different angles, different results

Noise measurements are an extremely complex topic. Imagine you have ten different sound sources. The noise from each will radiate through the space in different ways, and measuring ‘which is the noisiest’ and coming up with a clear verdict on that is a really hard nut to crack. To give you a better idea, we’ve interviewed Noctua. Different measurement techniques yield potentially different and sometimes contradictory conclusions. Read more “Noctua on measuring fan noise: Different angles, different results” »

  •  
  •  
  •  

Noctua NF-A14x25r on a radiator. Tested with DIY frame

Due to the atypical spacing of the mounting holes for its format, the new Noctua NF-A14x25r G2 PWM fans cannot be installed in 140mm positions as standard. You need a conversion frame for that, and one such frame was designed, made and sent to us by an HWCooling reader. So, we were able to simulate and test one of the most anticipated fans of recent years (NF-A14x25 G2 PWM) already now. Read more “Noctua NF-A14x25r on a radiator. Tested with DIY frame” »

  •  
  •  
  •  

Leave a Reply

Your email address will not be published. Required fields are marked *