Gigabyte Aorus 120 ARGB: Not just stylish, but a proper fan

… and airflow

To write that we have something mapped out to the last detail is perhaps too bold, but after proper preparation, few pieces of hardware are as easy to evaluate as fans. Of course, this had to be preceded by long preparations, developing a methodology, but you already know the story. What you don’t know yet is the first fruit, or rather the results of Akasa, SilentiumPC, SilverStone, Xigmatek or more exotic Reeven fans.

… and airflow

With airflow measurements, we can well explain why the test tunnel is shaped the way it is. It doesn’t consist of two parts just so that the “exhaust” can be conveniently clogged for pressure measurements. The anemometer (i.e. the wind speed measuring instrument) is held together by two parts, two formations, through the flanges.
The front part, at the beginning of which the fan is mounted, becomes steadily narrower and from about two thirds of the way through the cross-section is smaller than that of a 120 mm fan. The reason for this is that the cross-section of the anemometer is always smaller than that of the fans tested. The taper towards the anemometer fan is as smooth as could be chosen and the tunnel walls are smooth. This has minimized the occurrence of unnatural turbulence.
The difference between the cross section at the intake (fan under test) and at the constriction point (anemometer) also means a difference in dynamic pressure, the principles of the Venturi effect apply here. In order to avoid distortion at this level and to ensure that the fan airflow is not different from what it actually is, the Bernoulli equation must be applied to the measured values (for maximum accuracy, the calculation also takes into account the internal cross-sectional area of the anemometer, i.e. its inactive part ). After all this, it is again possible to confront our results with the paper parameters.

We use an Extech AN300 anemometer with a large 100 mm fan for the measurements. Its big advantage over other anemometers is that it is made for bidirectional sensing. This allows tests at different fan orientations. However, the “pull” position is more suitable or accurate for measurements, even though it may not seem so at first glance, but we’ll explain.

Here, we get to the second part of the tunnel, the part behind the anemometer. It is part of the whole device, mainly to allow a laminar flow of air to arrive at the rotor of the anemometer. Otherwise, uncontrolled side whirls would be reflected in the results, which are inconsistent with accurate measurements. Therefore, we will test the flow in the pull position. If anyone would like us to elaborate more on this topic, we can elaborate further at any time in the discussion below the article. Ask away. 🙂

The rear of the tunnel ensures, among other things, that the air supply to the anemometer fan is laminar

In connection with the anemometer, we will return a little more to the noise measurements and to the setting of modes according to fixed noise levels. It may have occurred to you as you were reading that the anemometer fan is also a source of sound that needs to be filtered out when testing fans. For this reason, we insert a belay pad between the frame and the anemometer fan before each measurement and mode setting according to the fixed noise level.


  •  
  •  
  •  
Flattr this!

We wrote 7 years ago. Tests you may have overlooked

Some articles become obsolete faster, others are relevant for a long time. Such, more durable ones usually do not focus on a specific product, but on a topic as a whole, with a pinch of generality. Articles like this have always been given space around here, since the beginning of HWCooling, and it probably doesn’t hurt to bring them up again. Well, at least as part of this selection which would be a shame to miss forever. Read more “We wrote 7 years ago. Tests you may have overlooked” »

  •  
  •  
  •  

Noctua on measuring fan noise: Different angles, different results

Noise measurements are an extremely complex topic. Imagine you have ten different sound sources. The noise from each will radiate through the space in different ways, and measuring ‘which is the noisiest’ and coming up with a clear verdict on that is a really hard nut to crack. To give you a better idea, we’ve interviewed Noctua. Different measurement techniques yield potentially different and sometimes contradictory conclusions. Read more “Noctua on measuring fan noise: Different angles, different results” »

  •  
  •  
  •  

Noctua NF-A14x25r on a radiator. Tested with DIY frame

Due to the atypical spacing of the mounting holes for its format, the new Noctua NF-A14x25r G2 PWM fans cannot be installed in 140mm positions as standard. You need a conversion frame for that, and one such frame was designed, made and sent to us by an HWCooling reader. So, we were able to simulate and test one of the most anticipated fans of recent years (NF-A14x25 G2 PWM) already now. Read more “Noctua NF-A14x25r on a radiator. Tested with DIY frame” »

  •  
  •  
  •  

Leave a Reply

Your email address will not be published. Required fields are marked *