Gigabyte Aorus 120 ARGB: Not just stylish, but a proper fan

.. and sound color (frequency characteristic)

To write that we have something mapped out to the last detail is perhaps too bold, but after proper preparation, few pieces of hardware are as easy to evaluate as fans. Of course, this had to be preceded by long preparations, developing a methodology, but you already know the story. What you don’t know yet is the first fruit, or rather the results of Akasa, SilentiumPC, SilverStone, Xigmatek or more exotic Reeven fans.

33 dBA or 33 dBA

The noise level, given as a single dBA value, is good for quick reference, but it doesn’t give you an idea of exactly what the sound sounds like. That’s because it averages a mix of noise levels of all frequencies of sound. One fan may disturb you more than the other, even though they both reach exactly the same dBA, yet each is characterized by different dominant (louder) frequencies. To analyze thoroughly with an idea of the “color” of the sound, it is essential to record and assess noise levels across the entire spectrum of frequencies that we perceive.

Spectrograph with noise levels at individual sound frequencies

We already do this in graphics card tests, and we’ll do it for fans too, where it makes even more sense. Using the UMIK-1 miniDSP microphone and TrueRTA’s mode-specific, fixed dBA application, we also measure which frequencies contribute more and which contribute less to the sound. The monitored frequency range is 20-20,000 Hz, which we’ll work with at a fine resolution of 1/24 octave. In it, noise levels from 20 Hz to 20 000 Hz are captured at up to 240 frequencies.

The information captured in the spectrograph is a bit more than we will need for clear fan comparisons. While you’ll always find a complete spectrograph in the tests, we’ll only work with the dominant frequencies (and their noise intensities) in the low, mid, and high bands in the comparison tables and charts. The low frequency band is represented by 20–200 Hz, the medium by 201–2000 Hz and the high by 2001–20 000 Hz. From each of these three bands, we select the dominant frequency, i.e. the loudest one, which contributes most to the composition of the sound.

To the dominant frequency we also give the intensity of its noise. However, in this case it is in a different decibel scale than those you are used to from noise meter measurements. Instead of dBA, we have dBu. This is a finer scale, which is additionally expressed negatively. Be careful of this when studying the results – a noise intensity of -70 dBu is higher than -75 dBu. We discussed this in more detail in the article Get familiar with measuring the frequency response of sound.

Strict acoustic safeguards are required to ensure that these measurements can be carried out with satisfactory repeatability at all. We use acoustic panels to measure the same values at all frequencies across repeated measurements. These ensure that the sound is always reflected equally to the microphone regardless of the distribution of other objects we have in the testlab. The baseline noise level before each measurement is also naturally the same. The room in which we measure is soundproofed.

To accurately measure the frequency characteristics of sound, it is important to maintain acoustic conditions at all times. We use a set of acoustic panels to create these.

Like the noise meter, the microphone has a parabolic collar to increase resolution. The latter is specially in this case not only to amplify but also to filter out the noises that occur whether we want them or not behind the microphone. We are talking about the physical activity of the user (tester). Without this addition, human breathing, for example, would also be picked up by the spectrograph. However, this is successfully reflected off the microphone sensor by the back (convex) side of the collar. As a result, the spectrogram only contains information about the sound emitted by the fan itself.


  •  
  •  
  •  
Flattr this!

Noctua on measuring fan noise: Different angles, different results

Noise measurements are an extremely complex topic. Imagine you have ten different sound sources. The noise from each will radiate through the space in different ways, and measuring ‘which is the noisiest’ and coming up with a clear verdict on that is a really hard nut to crack. To give you a better idea, we’ve interviewed Noctua. Different measurement techniques yield potentially different and sometimes contradictory conclusions. Read more “Noctua on measuring fan noise: Different angles, different results” »

  •  
  •  
  •  

Noctua NF-A14x25r on a radiator. Tested with DIY frame

Due to the atypical spacing of the mounting holes for its format, the new Noctua NF-A14x25r G2 PWM fans cannot be installed in 140mm positions as standard. You need a conversion frame for that, and one such frame was designed, made and sent to us by an HWCooling reader. So, we were able to simulate and test one of the most anticipated fans of recent years (NF-A14x25 G2 PWM) already now. Read more “Noctua NF-A14x25r on a radiator. Tested with DIY frame” »

  •  
  •  
  •  

DeepCool also brings new ARGB fans to Gamescom (2024)

Starting August 21, DeepCool, among others, will be among the vendors at Gamescom 2024. There will be a lot of cooling hardware at their booth that you haven’t been able to come in contact with yet because it’s not sold yet. But now you can come and see live, for example, fans from the FT or FD series (with ARGB LED) and a good attraction is also the Assassin IV VC Vision and many more, still shrouded in a veil of secrecy. Read more “DeepCool also brings new ARGB fans to Gamescom (2024)” »

  •  
  •  
  •  

Leave a Reply

Your email address will not be published. Required fields are marked *