To provide the best experiences, we and our partners use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us and our partners to process personal data such as browsing behavior or unique IDs on this site and show (non-) personalized ads. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Click below to consent to the above or make granular choices. Your choices will be applied to this site only. You can change your settings at any time, including withdrawing your consent, by using the toggles on the Cookie Policy, or by clicking on the manage consent button at the bottom of the screen.
Technické uloženie alebo prístup sú nevyhnutne potrebné na legitímny účel umožnenia použitia konkrétnej služby, ktorú si účastník alebo používateľ výslovne vyžiadal, alebo na jediný účel vykonania prenosu komunikácie cez elektronickú komunikačnú sieť.
Technické uloženie alebo prístup je potrebný na legitímny účel ukladania preferencií, ktoré si účastník alebo používateľ nepožaduje.
Technické úložisko alebo prístup, ktorý sa používa výlučne na štatistické účely.
Technické úložisko alebo prístup, ktorý sa používa výlučne na anonymné štatistické účely. Bez predvolania, dobrovoľného plnenia zo strany vášho poskytovateľa internetových služieb alebo dodatočných záznamov od tretej strany, informácie uložené alebo získané len na tento účel sa zvyčajne nedajú použiť na vašu identifikáciu.
Technické úložisko alebo prístup sú potrebné na vytvorenie používateľských profilov na odosielanie reklamy alebo sledovanie používateľa na webovej stránke alebo na viacerých webových stránkach na podobné marketingové účely.
Hmm, the 100th fan in the database—counting 140 mm models as well. On Thursday, we’ll do a kind of recap or summary, where all fans tested so far will appear together in the charts. 🙂
After reading the methodology section I’m still uncertain about when the tests were performed with the obstacles infront or behind the fan. Could you please clarify that?
Scenario by scenario, it varies. The radiators (both thinner and thicker ones) are behind the fans, as they are more commonly used in practice, while the dust filters (both nylon and plastic) are in front of them, i.e. in front of the impeller. That also makes more sense.
There is also a hexagonal grille in front of the fan, on the intake side, although in PC cases (for example, on the exhaust) it is often located behind it. We chose this placement because having it behind the impeller doesn’t change the acoustic profile very much, whereas with the opposite orientation, the difference can sometimes be quite significant, especially when it comes to tonal peaks. 🙂
Thanks for the clarification!
Your setup is what I was hoping for, for the reasons you already stated yourself. And just to make sure I’m not misunderstanding a fine detail: Whether **reverse blade fan or regular fan**, your dust filter test setup (both nylon an plastic) will always reflect typical real world usage, i.e. air will be “pulled” through the filter instead of being “pushed” through it. Right? Thanks in advance!
Yes, the dust filters are always on the intake side of the fans. 🙂
For the most accurate comparison possible, reverse fans are also positioned in the same relationship to the anemometer (in pull). That’s a more complicated discussion, but this is always the case regardless of the fan. If we did it the opposite way, in push, the area where we measure the wind/air speed—which is subsequently used to calculate the airflow in cubic units—would be too turbulent, and the results would therefore be distorted. 🙂