Some really attractive things are often overlooked or given less attention than they deserve, for various reasons. This is somewhat the case with the technically remarkable fan from PCCooler CPS – the F5 R120. This 120 mm fan with its features is in the company of the most prominent names, although it has its weaknesses as well. These may or may not interest you either. It depends on the use case.
Measurement of static pressure…
Finally, it is time to move further down the tunnel a bit. Just behind the fan is a static pressure sensing probe. Its position has been chosen with maximum measurement efficiency in mind. In other words, the sensors are placed at the points of highest pressure (although this is virtually the same everywhere in the unconstrained part of the tunnel).
The Fieldpiece ASP2, which is connected to the Fieldpiece SDMN5 manometer, is used to measure the static pressure in the tunnel. The latter also allows measurements in millimetres of water column, but we measure in millibars. This is a more finely resolved base unit for this meter. And only from there we convert the measured values into mm H2O to allow easy comparison with what the manufacturers state.

While we wrote when measuring noise levels that our results could not be compared with the parameters, that is no longer the case here. As long as the fan manufacturers do not embellish the parameters, they should quote approximately the same pressure values as our tests show. The most significant deviations can only arise at the level of varying accuracy of the measuring instruments, but these are negligible percentages.

The greater the difference between the manufacturer’s claimed values and ours, the less the specifications correspond to reality. If the claimed values are significantly higher, it is certainly an intention to artificially give an advantage to the fans on the market. However, if the manufacturer quotes a lower pressure value than we do, it points to something else. Namely, a weaker tightness of the measuring environment. The less tight the tunnel is, the lower the pressure you naturally measure. This is one of the things we tuned for an extremely long time, but in the end we ironed out all the weak spots. Whether it’s the passage for the probe itself, the flanges around the anemometer, even the anemometer frame itself, which is made up of two parts, needed to be sealed in the middle. Finally, the flap at the tunnel outlet must also be perfectly tight. That’s because static pressure has to be measured in zero airflow.

But there is one thing that often lowers the pressure of the fans a bit. And that’s protruding anti-vibration pads in the corners or otherwise protruding corners. In other words, when the fan doesn’t fit perfectly to the mounting frame at the inlet, and there are small gaps around the perimeter, that also affects what you measure. But we have not gone into this because it is already a quality feature of the fan. In the same way, it will “stand out” and perform a bit weaker than it has the potential to do with better workmanship, even after application by the end user.







That’s a very a good fan overall. No noticeable weakness with decent noise profile, at a highly competitive price point. I’m surprised that a PBT only fan without an outer ring can perform this well. I wonder how the Arctic P12 Max compares (maybe it’s comparable to the ARGB version?)
P.S. Frequency plots aren’t accessible in the English version, and most (all?) links in the conclusion page are broken due to lacking -bk.
Thanks! Fixed. 🙂
The motor sound link is still broken. It’s the first plot in the “hexagonal grille” page, right?
So, this sound only appears when speed is very close to the minimum RPM? I don’t think I’ve seen this behaviour before, interesting. It should be easily avoidable by the user, but can be limiting for those who want an extremely quiet build.
Haha, no mistake escapes you. What a great thing that we have such attentive readers. 🙂
And yes, it’s the first spectrogram with the hexagonal grille. This mode has the lowest fan speed at which frequency analysis of sound is measured. Several fans with typically cheaper motors are struggling at the lower speed limit and this behaviour is accompanied by such annoying sounds. I don’t always point it out, but here it was extra interesting especially in the context of high efficiency at very low speeds. When you go from that optimum 700 rpm down to somewhere near 550 rpm, it may not be so great anymore. Because of that annoying motor sound that adds to the well audible spectrum.
The blades of the F5 R120 are relatively short yet thick. Although we did measure some vibration, I don’t think it was due to the blades being “too flexible”. Something else will be behind their occurrence, maybe some manufacturing inaccuracies (around the axle for example) and such. The lower MTBF value would suggest this, but I don’t want to speculate on these things.
What is obvious, however, is that even a cheap fan with shorter PBT blades doesn’t have to be the source of any vibration. We have already been convinced of this by a test of 15 Stratus 1220 PWMs, where the variance of vibration across the samples is very wide. But it is given by the high tolerances. If the vibrations were due to blade undulations, we would never, on any piece, measure 0.000. And in that one case (the gold sample) this happened even at maximum speed with a fairly high (1600) RPM.
Strongly recommand you to add the 9RA1212P4G001, and maybe the 9RA1212P1K001 and 9RA1412P1G001 from Sanyo into the compaing list.
Thank you for the useful tips. We will definitely take a look at the fans and try to add them to the results database. I can’t promise when this might happen, but we will contact Sanyo and see.